2012Metallurgical AnalysisRequires access

Determination of trace antimony in galvanized plate coating by hydride generation-atomic fluorescence spectrometry

Wang Ming-hai

Open publisher page 0 citations

Abstract

After investigating the instrument parameters,matrix effect of zinc,concentration of hexamethylene tetramine in stripping solution,degree of acidity and dosage of HF,a new method for determination of trace antimony in coating of galvanized plate by hydride generation-atomic fluorescence spectrometry has been established.The results indicated that matrix effect of zinc was avoided by matrix matching,40% HCl(V/V) was fit for measurement,dosage of HF less than 2 mL needed for digestion of samples and hexamethylene tetramine in stripping solution almost do not influence the determination of antimony.The fluorescence intensity was linear with the concentration of antimony in the range of 0.001-0.1 μg/mL,with detection limit of 0.2 μg/L.The proposed method has been applied for two galvanized plate samples.The relative standard deviation(RSD) was 1.0% and 1.2%.The recovery rate of antimony was 96%-101%.The results of this method were in a good agreement with those obtained by ICP-MS.

About this research paper

What this paper is about

After investigating the instrument parameters,matrix effect of zinc,concentration of hexamethylene tetramine in stripping solution,degree of acidity and dosage of HF,a new method for determination of trace antimony in coating of galvanized plate by hydride generation-atomic fluorescence spectrometry has been established.The results indicated that matrix effect of zinc was avoided by matrix matching,40% HCl(V/V) was fit for measurement,dosage of HF less than 2 mL needed for digestion of samples and hexamethylene tetramine in stripping solution almost do not influence the determination of antimony.The fluorescence intensity was linear with the concentration of antimony in the range of 0.001-0.1 μg/mL,with detection limit of 0.2 μg/L.The proposed method has been applied for two galvanized plate samples.The relative standard deviation(RSD) was 1.0% and 1.2%.The recovery rate of antimony was 96%-101%.The results of this method were in a good agreement with those obtained by ICP-MS.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

After investigating the instrument parameters,matrix effect of zinc,concentration of hexamethylene tetramine in stripping solution,degree of acidity and dosage of HF,a new method for determination of trace antimony in coating of galvanized plate by hydride generation-atomic fluorescence spectrometry has been established.The results indicated that matrix effect of zinc was avoided by matrix matching,40% HCl(V/V) was fit for measurement,dosage of HF less than 2 mL needed for digestion of samples and hexamethylene tetramine in stripping solution almost do not influence the determination of antimony.The fluorescence intensity was linear with the concentration of antimony in the range of 0.001-0.1 μg/mL,with detection limit of 0.2 μg/L.The proposed method has been applied for two galvanized plate samples.The relative standard deviation(RSD) was 1.0% and 1.2%.The recovery rate of antimony was 96%-101%.The results of this method were in a good agreement with those obtained by ICP-MS.

Key concepts: Antimony, Detection limit, Tetramine, Chemistry, Stripping (fiber), Zinc, Hydride, Matrix (chemical analysis)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of trace antimony in galvanized plate coating by hydride generation-atomic fluorescence spectrometry — Research Paper | ScholarLens