2008Metallurgical AnalysisRequires access

Inductively coupled plasma atomic emission spectrometric determination of impurity elements in tin concentrate

Chen Yong-xin

Open publisher page 1 citations

Abstract

Tin concentrate ore sample was digested with HCl-HNO3 mixed acid.After separating tin by hydrolysis,the impurity elements including lead,arsenic,copper,zinc and bismuth were determined by inductively coupled plasma atomic emission spectrometry.The dissolution conditions,determination medium,interference between matrix and coexisted elements were discussed.20 fold amount of Mg,Ca and W,100 fold amount of Ca,iron with mass fraction less than 10% had negligible interference to detected elements.The matrix effect of this method was small,and there was no remarkable interference between tested elements.Under the optimal working conditions of equipment,the recovery was 85%-102%,the relative standard deviation(RSD,n=12) was 0.91%-2.36%.When this method was used to analyze the standard sample and actual sample,the results were in accordant with certified values and values obtained by other determination methods within the allowable error range.This method was applicable to the detection of large amounts of tin concentrate ores in import and export inspection.

About this research paper

What this paper is about

Tin concentrate ore sample was digested with HCl-HNO3 mixed acid.After separating tin by hydrolysis,the impurity elements including lead,arsenic,copper,zinc and bismuth were determined by inductively coupled plasma atomic emission spectrometry.The dissolution conditions,determination medium,interference between matrix and coexisted elements were discussed.20 fold amount of Mg,Ca and W,100 fold amount of Ca,iron with mass fraction less than 10% had negligible interference to detected elements.The matrix effect of this method was small,and there was no remarkable interference between tested elements.Under the optimal working conditions of equipment,the recovery was 85%-102%,the relative standard deviation(RSD,n=12) was 0.91%-2.36%.When this method was used to analyze the standard sample and actual sample,the results were in accordant with certified values and values obtained by other determination methods within the allowable error range.This method was applicable to the detection of large amounts of tin concentrate ores in import and export inspection.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Tin concentrate ore sample was digested with HCl-HNO3 mixed acid.After separating tin by hydrolysis,the impurity elements including lead,arsenic,copper,zinc and bismuth were determined by inductively coupled plasma atomic emission spectrometry.The dissolution conditions,determination medium,interference between matrix and coexisted elements were discussed.20 fold amount of Mg,Ca and W,100 fold amount of Ca,iron with mass fraction less than 10% had negligible interference to detected elements.The matrix effect of this method was small,and there was no remarkable interference between tested elements.Under the optimal working conditions of equipment,the recovery was 85%-102%,the relative standard deviation(RSD,n=12) was 0.91%-2.36%.When this method was used to analyze the standard sample and actual sample,the results were in accordant with certified values and values obtained by other determination methods within the allowable error range.This method was applicable to the detection of large amounts of tin concentrate ores in import and export inspection.

Key concepts: Tin, Arsenic, Chemistry, Inductively coupled plasma, Analytical Chemistry (journal), Impurity, Inductively coupled plasma mass spectrometry, Zinc

Related papers

Back to paper searchBrowse research topicsOriginal source
Inductively coupled plasma atomic emission spectrometric determination of impurity elements in tin concentrate — Research Paper | ScholarLens