A New Model for Wet Gas Flow Measurement with V-Cone Meter
Bai Bofeng
Abstract
Bai Bofeng
Abstract
The two-phase flow coefficient of a V-cone meter was proposed to correct the over-reading produced by measuring the wet gas using the V-cone meter.The experiment was conducted with the V-cone meter with a diameter ratio of 0.75 for air and water.The test pressure ranged from 0.10 MPa to 0.22 MPa,and the gas and liquid mass flow rates were from 100 m3·h-1 to 300 m3·h-1 and from 0 to 0.08 m3·h-1,respectively.The effects of the Lockhart-Martinelli parameter,the operating pressure and the gas densiometric Froude number on the two-phase flow coefficient were investigated.The results show that the two-phase flow coefficient increased linearly with the Lockhart-Martinelli parameter,and the slope of the two-phase flow coefficient vs.the Lockhart-Martinelli parameter was affected by the gas densiometric Froude number and the pressure.The correlation between the two-phase flow coefficient and the Lockhart-Martinelli parameter,the gas densiometric Froude number and the pressure was obtained.On the basis of the two-phase flow coefficient,the wet gas model was developed.The relative error of the gas mass flow rate predicted by the model is within ±5.0% at the 95% confidence level.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The two-phase flow coefficient of a V-cone meter was proposed to correct the over-reading produced by measuring the wet gas using the V-cone meter.The experiment was conducted with the V-cone meter with a diameter ratio of 0.75 for air and water.The test pressure ranged from 0.10 MPa to 0.22 MPa,and the gas and liquid mass flow rates were from 100 m3·h-1 to 300 m3·h-1 and from 0 to 0.08 m3·h-1,respectively.The effects of the Lockhart-Martinelli parameter,the operating pressure and the gas densiometric Froude number on the two-phase flow coefficient were investigated.The results show that the two-phase flow coefficient increased linearly with the Lockhart-Martinelli parameter,and the slope of the two-phase flow coefficient vs.the Lockhart-Martinelli parameter was affected by the gas densiometric Froude number and the pressure.The correlation between the two-phase flow coefficient and the Lockhart-Martinelli parameter,the gas densiometric Froude number and the pressure was obtained.On the basis of the two-phase flow coefficient,the wet gas model was developed.The relative error of the gas mass flow rate predicted by the model is within ±5.0% at the 95% confidence level.
Key concepts: Froude number, Mass flow meter, Wet gas, Flow measurement, Flow (mathematics), Flow coefficient, Correlation coefficient, Mechanics