2009•Central South PharmacyRequires access

Determination of simvastatin in human plasma by HPLC-MS/MS and bioequivalence study in healthy volunteers

Lin Shu-guang

Open publisher page 0 citations

Abstract

Objective To improve the determination of human plasma simvastatin,study the relative bioavailability of Simvastatin tablets,and evaluate the bioequivalence.Methods A single oral dose of 40 mg test and reference formulations was given to 20 healthy volunteers in a randomized cross-over study.Sample(0.2 mL) was determined by HPLC-MS/MS after being extracted by 1 mL diethyl ether.DAS 2.0 was used to assess the relative bioavailability and bioequivalence of Simvastatin tablets.Results The linear range of the calibration curves was 0.1~20 ng·mL-1 for simvastatin with a lower limit of quantitation(0.1 ng·mL-1).Within-and between-run precision was less than 6%.Accuracy ranged from 101% to 109%.The recovery was more than 82%.The main pharmacokinetic parameters t1/2,tmax,Cmax,AUC0~t and AUC0~∞ of the two formulations were as follows:(5.3±5.1)h,(2.2±0.7)h,(4.6±3.0)ng·mL-1,(24.3±15.7) ng·h ·mL-1,(27.5±21.6) ng·h ·mL-1 and(4.5±6.7)h,(1.9±0.7)h,(5.0±3.0) ng·mL-1,(21.4±13.4) ng·h ·mL-1,(23.9±21.2) ng·h ·mL-1.Relative bioavailability of Simvastatin test reference was 113.1%±17.4%.Conclusion The present method is sensitive and reliable.The method described herein has been successfully used for the bioequivalence study of simvastatin formulation.The test and reference simvastatin tablets are bioequivalent.

About this research paper

What this paper is about

Objective To improve the determination of human plasma simvastatin,study the relative bioavailability of Simvastatin tablets,and evaluate the bioequivalence.Methods A single oral dose of 40 mg test and reference formulations was given to 20 healthy volunteers in a randomized cross-over study.Sample(0.2 mL) was determined by HPLC-MS/MS after being extracted by 1 mL diethyl ether.DAS 2.0 was used to assess the relative bioavailability and bioequivalence of Simvastatin tablets.Results The linear range of the calibration curves was 0.1~20 ng·mL-1 for simvastatin with a lower limit of quantitation(0.1 ng·mL-1).Within-and between-run precision was less than 6%.Accuracy ranged from 101% to 109%.The recovery was more than 82%.The main pharmacokinetic parameters t1/2,tmax,Cmax,AUC0~t and AUC0~∞ of the two formulations were as follows:(5.3±5.1)h,(2.2±0.7)h,(4.6±3.0)ng·mL-1,(24.3±15.7) ng·h ·mL-1,(27.5±21.6) ng·h ·mL-1 and(4.5±6.7)h,(1.9±0.7)h,(5.0±3.0) ng·mL-1,(21.4±13.4) ng·h ·mL-1,(23.9±21.2) ng·h ·mL-1.Relative bioavailability of Simvastatin test reference was 113.1%±17.4%.Conclusion The present method is sensitive and reliable.The method described herein has been successfully used for the bioequivalence study of simvastatin formulation.The test and reference simvastatin tablets are bioequivalent.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To improve the determination of human plasma simvastatin,study the relative bioavailability of Simvastatin tablets,and evaluate the bioequivalence.Methods A single oral dose of 40 mg test and reference formulations was given to 20 healthy volunteers in a randomized cross-over study.Sample(0.2 mL) was determined by HPLC-MS/MS after being extracted by 1 mL diethyl ether.DAS 2.0 was used to assess the relative bioavailability and bioequivalence of Simvastatin tablets.Results The linear range of the calibration curves was 0.1~20 ng·mL-1 for simvastatin with a lower limit of quantitation(0.1 ng·mL-1).Within-and between-run precision was less than 6%.Accuracy ranged from 101% to 109%.The recovery was more than 82%.The main pharmacokinetic parameters t1/2,tmax,Cmax,AUC0~t and AUC0~∞ of the two formulations were as follows:(5.3±5.1)h,(2.2±0.7)h,(4.6±3.0)ng·mL-1,(24.3±15.7) ng·h ·mL-1,(27.5±21.6) ng·h ·mL-1 and(4.5±6.7)h,(1.9±0.7)h,(5.0±3.0) ng·mL-1,(21.4±13.4) ng·h ·mL-1,(23.9±21.2) ng·h ·mL-1.Relative bioavailability of Simvastatin test reference was 113.1%±17.4%.Conclusion The present method is sensitive and reliable.The method described herein has been successfully used for the bioequivalence study of simvastatin formulation.The test and reference simvastatin tablets are bioequivalent.

Key concepts: Bioequivalence, Simvastatin, Bioavailability, Cmax, Pharmacokinetics, Chromatography, Chemistry, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of simvastatin in human plasma by HPLC-MS/MS and bioequivalence study in healthy volunteers — Research Paper | ScholarLens