2006Chongqing Yike Daxue xuebaoRequires access

Clinical observation on efficacy of radiofrequency ablation for focal atrial tachycardia

Zengzhang Liu

Open publisher page 0 citations

Abstract

Objective:To investigate the efficacy and safety of catheter radiofrequency ablation for focal atrial tachycardia,by comparing conventional mapping group and Carto system mapping group.Methods:50 patients with focal atrial tachycardia underwent electrophysiologic study and radiofrequency ablation.32 cases were in conventional mapping group,and 25 cases in Carto system mapping group,including 7 cases with unsuccessful ablation in conventional mapping group.During follow-up 20±11 months,radiofrequency ablation acute successful rate,long-term successful rate,safety,and the clinical symptoms were recorded.ⅹ-ray radiation exposure time was compared between conventional mapping group and Carto system mapping group.Results: ① radiofrequency ablation acute successful rate of conventional mapping group and Carto system mapping group were 78% and 100%,and long-term successful rate were 68% and 96% respectively.No complications occurred.The clinical symptoms caused by focal atrial tachycardia disappeared after successful ablation.② ⅹ-ray radiation exposure time of Carto system mapping group was shorter than that of conventional mapping group.Conclusions: Successful rate and safety of radiofrequency ablation of focal atrial tachycardia were higher,and effects of Carto system mapping group were better than those of conventional mapping group.And X-ray radiation exposure time of Carto system mapping group decreased.

About this research paper

What this paper is about

Objective:To investigate the efficacy and safety of catheter radiofrequency ablation for focal atrial tachycardia,by comparing conventional mapping group and Carto system mapping group.Methods:50 patients with focal atrial tachycardia underwent electrophysiologic study and radiofrequency ablation.32 cases were in conventional mapping group,and 25 cases in Carto system mapping group,including 7 cases with unsuccessful ablation in conventional mapping group.During follow-up 20±11 months,radiofrequency ablation acute successful rate,long-term successful rate,safety,and the clinical symptoms were recorded.ⅹ-ray radiation exposure time was compared between conventional mapping group and Carto system mapping group.Results: ① radiofrequency ablation acute successful rate of conventional mapping group and Carto system mapping group were 78% and 100%,and long-term successful rate were 68% and 96% respectively.No complications occurred.The clinical symptoms caused by focal atrial tachycardia disappeared after successful ablation.② ⅹ-ray radiation exposure time of Carto system mapping group was shorter than that of conventional mapping group.Conclusions: Successful rate and safety of radiofrequency ablation of focal atrial tachycardia were higher,and effects of Carto system mapping group were better than those of conventional mapping group.And X-ray radiation exposure time of Carto system mapping group decreased.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To investigate the efficacy and safety of catheter radiofrequency ablation for focal atrial tachycardia,by comparing conventional mapping group and Carto system mapping group.Methods:50 patients with focal atrial tachycardia underwent electrophysiologic study and radiofrequency ablation.32 cases were in conventional mapping group,and 25 cases in Carto system mapping group,including 7 cases with unsuccessful ablation in conventional mapping group.During follow-up 20±11 months,radiofrequency ablation acute successful rate,long-term successful rate,safety,and the clinical symptoms were recorded.ⅹ-ray radiation exposure time was compared between conventional mapping group and Carto system mapping group.Results: ① radiofrequency ablation acute successful rate of conventional mapping group and Carto system mapping group were 78% and 100%,and long-term successful rate were 68% and 96% respectively.No complications occurred.The clinical symptoms caused by focal atrial tachycardia disappeared after successful ablation.② ⅹ-ray radiation exposure time of Carto system mapping group was shorter than that of conventional mapping group.Conclusions: Successful rate and safety of radiofrequency ablation of focal atrial tachycardia were higher,and effects of Carto system mapping group were better than those of conventional mapping group.And X-ray radiation exposure time of Carto system mapping group decreased.

Key concepts: Radiofrequency ablation, Medicine, Ablation, Atrial tachycardia, Tachycardia, Catheter ablation, Internal medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical observation on efficacy of radiofrequency ablation for focal atrial tachycardia — Research Paper | ScholarLens