Clinical observation on efficacy of radiofrequency ablation for focal atrial tachycardia
Zengzhang Liu
Abstract
Zengzhang Liu
Abstract
Objective:To investigate the efficacy and safety of catheter radiofrequency ablation for focal atrial tachycardia,by comparing conventional mapping group and Carto system mapping group.Methods:50 patients with focal atrial tachycardia underwent electrophysiologic study and radiofrequency ablation.32 cases were in conventional mapping group,and 25 cases in Carto system mapping group,including 7 cases with unsuccessful ablation in conventional mapping group.During follow-up 20±11 months,radiofrequency ablation acute successful rate,long-term successful rate,safety,and the clinical symptoms were recorded.ⅹ-ray radiation exposure time was compared between conventional mapping group and Carto system mapping group.Results: ① radiofrequency ablation acute successful rate of conventional mapping group and Carto system mapping group were 78% and 100%,and long-term successful rate were 68% and 96% respectively.No complications occurred.The clinical symptoms caused by focal atrial tachycardia disappeared after successful ablation.② ⅹ-ray radiation exposure time of Carto system mapping group was shorter than that of conventional mapping group.Conclusions: Successful rate and safety of radiofrequency ablation of focal atrial tachycardia were higher,and effects of Carto system mapping group were better than those of conventional mapping group.And X-ray radiation exposure time of Carto system mapping group decreased.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To investigate the efficacy and safety of catheter radiofrequency ablation for focal atrial tachycardia,by comparing conventional mapping group and Carto system mapping group.Methods:50 patients with focal atrial tachycardia underwent electrophysiologic study and radiofrequency ablation.32 cases were in conventional mapping group,and 25 cases in Carto system mapping group,including 7 cases with unsuccessful ablation in conventional mapping group.During follow-up 20±11 months,radiofrequency ablation acute successful rate,long-term successful rate,safety,and the clinical symptoms were recorded.ⅹ-ray radiation exposure time was compared between conventional mapping group and Carto system mapping group.Results: ① radiofrequency ablation acute successful rate of conventional mapping group and Carto system mapping group were 78% and 100%,and long-term successful rate were 68% and 96% respectively.No complications occurred.The clinical symptoms caused by focal atrial tachycardia disappeared after successful ablation.② ⅹ-ray radiation exposure time of Carto system mapping group was shorter than that of conventional mapping group.Conclusions: Successful rate and safety of radiofrequency ablation of focal atrial tachycardia were higher,and effects of Carto system mapping group were better than those of conventional mapping group.And X-ray radiation exposure time of Carto system mapping group decreased.
Key concepts: Radiofrequency ablation, Medicine, Ablation, Atrial tachycardia, Tachycardia, Catheter ablation, Internal medicine, Cardiology