2012Journal of Beijing University of Traditional Chinese MedicineRequires access

Determination of plasma protein binding rate of betulinic acid

Lantong Zhang

Open publisher page 0 citations

Abstract

Objective To develop a method for determining the plasma protein binding rate of betulinic acid in rat plasma,human plasma and bovine serum albumin(BSA).Methods The plasma protein binding rate of betulinic acid was determined by using equilibrium dialysis.The concentration of plasma betulinic acid was determined by using HPLC.The plasma protein binding rate of betulinic acid was determined and compared in different serum samples.The HPLC procedure was performed on DiamonsilTM C18 column at 30 ℃.The mobile phase was acetonitrile-0.2% acetic acid(75∶ 25) in gradient elution,flow velocity was 1.0 mL/min and detection wavelength was 203 nm.Results When the concentration was from 50 mg/L to 100 mg/L,the concentration of betulinic acid had no significant influence on plasma protein binding rate.There was a significant difference between the plasma protein binding rate of betulinic acid in rat plasma and that in human plasma.The plasma protein binding rate of betulinic acid in human plasma was higher than that in rat plasma.Conclusion Betulic acid has a higher binding intension with plasma protein.HPLC for determining the plasma protein binding rate of betulinic acid is simple,rapid and sensitive with a higher selectivity.

About this research paper

What this paper is about

Objective To develop a method for determining the plasma protein binding rate of betulinic acid in rat plasma,human plasma and bovine serum albumin(BSA).Methods The plasma protein binding rate of betulinic acid was determined by using equilibrium dialysis.The concentration of plasma betulinic acid was determined by using HPLC.The plasma protein binding rate of betulinic acid was determined and compared in different serum samples.The HPLC procedure was performed on DiamonsilTM C18 column at 30 ℃.The mobile phase was acetonitrile-0.2% acetic acid(75∶ 25) in gradient elution,flow velocity was 1.0 mL/min and detection wavelength was 203 nm.Results When the concentration was from 50 mg/L to 100 mg/L,the concentration of betulinic acid had no significant influence on plasma protein binding rate.There was a significant difference between the plasma protein binding rate of betulinic acid in rat plasma and that in human plasma.The plasma protein binding rate of betulinic acid in human plasma was higher than that in rat plasma.Conclusion Betulic acid has a higher binding intension with plasma protein.HPLC for determining the plasma protein binding rate of betulinic acid is simple,rapid and sensitive with a higher selectivity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a method for determining the plasma protein binding rate of betulinic acid in rat plasma,human plasma and bovine serum albumin(BSA).Methods The plasma protein binding rate of betulinic acid was determined by using equilibrium dialysis.The concentration of plasma betulinic acid was determined by using HPLC.The plasma protein binding rate of betulinic acid was determined and compared in different serum samples.The HPLC procedure was performed on DiamonsilTM C18 column at 30 ℃.The mobile phase was acetonitrile-0.2% acetic acid(75∶ 25) in gradient elution,flow velocity was 1.0 mL/min and detection wavelength was 203 nm.Results When the concentration was from 50 mg/L to 100 mg/L,the concentration of betulinic acid had no significant influence on plasma protein binding rate.There was a significant difference between the plasma protein binding rate of betulinic acid in rat plasma and that in human plasma.The plasma protein binding rate of betulinic acid in human plasma was higher than that in rat plasma.Conclusion Betulic acid has a higher binding intension with plasma protein.HPLC for determining the plasma protein binding rate of betulinic acid is simple,rapid and sensitive with a higher selectivity.

Key concepts: Betulinic acid, Chemistry, Chromatography, High-performance liquid chromatography, Blood proteins, Acetic acid, Biochemistry, Biology

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of plasma protein binding rate of betulinic acid — Research Paper | ScholarLens