2008Journal of Guizhou University of TechnologyRequires access

Discussion on Several Problems about Stress Test on the Spot for a Long-Span Prestressed Concrete Continuous Rigid Frame Bridge

Bin Du

Open publisher page 1 citations

Abstract

During construction of a long span prestressed concrete continuous rigid frame bridge,a set of strain transducers are installed in its key sections for measuring the structural strains,With the help of error analysis,the stress test results of a long span prestressed concrete continuous rigid frame bridge are approximate to the actual structural stresses.It is the basis that can be used to analyze the structural stresses,modify the structural design and estimate the engineering quality.

About this research paper

What this paper is about

During construction of a long span prestressed concrete continuous rigid frame bridge,a set of strain transducers are installed in its key sections for measuring the structural strains,With the help of error analysis,the stress test results of a long span prestressed concrete continuous rigid frame bridge are approximate to the actual structural stresses.It is the basis that can be used to analyze the structural stresses,modify the structural design and estimate the engineering quality.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During construction of a long span prestressed concrete continuous rigid frame bridge,a set of strain transducers are installed in its key sections for measuring the structural strains,With the help of error analysis,the stress test results of a long span prestressed concrete continuous rigid frame bridge are approximate to the actual structural stresses.It is the basis that can be used to analyze the structural stresses,modify the structural design and estimate the engineering quality.

Key concepts: Rigid frame, Structural engineering, Prestressed concrete, Span (engineering), Bridge (graph theory), Frame (networking), Stress (linguistics), Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Discussion on Several Problems about Stress Test on the Spot for a Long-Span Prestressed Concrete Continuous Rigid Frame Bridge — Research Paper | ScholarLens