2008Guiding Journal of Traditional Chinese Medicine and PharmacyRequires access

Determination of Dipyridamole Concentration in Human Plasma by High Performance Liquid Chromatography with Fluorescence Detection

Qiuhong Tan

Open publisher page 0 citations

Abstract

Objective: To establish a simple and rapid method for determination of dipyridamole in human plasma by HPLC with fluorescence detection.Methods: Chromatographic column was KromasilC18(4.6 mm ′150 mm,5 μm) and 30℃ of column temperature.The mobile phase consisted of 0.02 mol·L-1 potassium dihydrogen phosphate(containing Triethylamine 0.04%)-acetonitrile(39:61) with a flow rate of 1.0 ml·min-1.A fluorescence detector was set atλex290nm,λem485 nm.Fluvastatin was used as internal standard.Results: The calibration curve was in good linearity over the range of 10~4000 μg·L-1(r=0.9997).The intra-day and inter-day RSD were less than 10%.Conclusion: The method is sensitive,rapid and suitable for the determination of dipyridamole in plasma.

About this research paper

What this paper is about

Objective: To establish a simple and rapid method for determination of dipyridamole in human plasma by HPLC with fluorescence detection.Methods: Chromatographic column was KromasilC18(4.6 mm ′150 mm,5 μm) and 30℃ of column temperature.The mobile phase consisted of 0.02 mol·L-1 potassium dihydrogen phosphate(containing Triethylamine 0.04%)-acetonitrile(39:61) with a flow rate of 1.0 ml·min-1.A fluorescence detector was set atλex290nm,λem485 nm.Fluvastatin was used as internal standard.Results: The calibration curve was in good linearity over the range of 10~4000 μg·L-1(r=0.9997).The intra-day and inter-day RSD were less than 10%.Conclusion: The method is sensitive,rapid and suitable for the determination of dipyridamole in plasma.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish a simple and rapid method for determination of dipyridamole in human plasma by HPLC with fluorescence detection.Methods: Chromatographic column was KromasilC18(4.6 mm ′150 mm,5 μm) and 30℃ of column temperature.The mobile phase consisted of 0.02 mol·L-1 potassium dihydrogen phosphate(containing Triethylamine 0.04%)-acetonitrile(39:61) with a flow rate of 1.0 ml·min-1.A fluorescence detector was set atλex290nm,λem485 nm.Fluvastatin was used as internal standard.Results: The calibration curve was in good linearity over the range of 10~4000 μg·L-1(r=0.9997).The intra-day and inter-day RSD were less than 10%.Conclusion: The method is sensitive,rapid and suitable for the determination of dipyridamole in plasma.

Key concepts: Chromatography, Chemistry, Dipyridamole, Triethylamine, High-performance liquid chromatography, Calibration curve, Fluorescence, Potassium

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Dipyridamole Concentration in Human Plasma by High Performance Liquid Chromatography with Fluorescence Detection — Research Paper | ScholarLens