2008Safety in Coal MinesRequires access

Study of Determination of Sulfur Hexafluoride as Mine Tracer Gas by Gas Chromatography with Electron Capture Detector

XU Hua-shan

Open publisher page 0 citations

Abstract

In this paper,a simple method for determination of SF6 as the mine tracer gas by Gas chromatography-Electron capture detector was developed.The operation parameters that affect separation effect of chromatography were studied.Under the optimized condition,there is good linearity relationship between the peak area and the concentration of SF6 over the range 5~400 ng/L(r=0.9995).The detection limits of 1 ng/L.The RSD were lower than 5%.The developed method had been used for the actual sample analysis.The results were satisfactory.

About this research paper

What this paper is about

In this paper,a simple method for determination of SF6 as the mine tracer gas by Gas chromatography-Electron capture detector was developed.The operation parameters that affect separation effect of chromatography were studied.Under the optimized condition,there is good linearity relationship between the peak area and the concentration of SF6 over the range 5~400 ng/L(r=0.9995).The detection limits of 1 ng/L.The RSD were lower than 5%.The developed method had been used for the actual sample analysis.The results were satisfactory.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper,a simple method for determination of SF6 as the mine tracer gas by Gas chromatography-Electron capture detector was developed.The operation parameters that affect separation effect of chromatography were studied.Under the optimized condition,there is good linearity relationship between the peak area and the concentration of SF6 over the range 5~400 ng/L(r=0.9995).The detection limits of 1 ng/L.The RSD were lower than 5%.The developed method had been used for the actual sample analysis.The results were satisfactory.

Key concepts: Electron capture detector, Sulfur hexafluoride, Gas chromatography, TRACER, Chemistry, Chromatography, Detector, Electron capture

Related papers

Back to paper searchBrowse research topicsOriginal source
Study of Determination of Sulfur Hexafluoride as Mine Tracer Gas by Gas Chromatography with Electron Capture Detector — Research Paper | ScholarLens