2010Journal of Atmospheric and Environmental OpticsRequires access

Measurements of Atmospheric Transmittance Based on Fourier Transform Infrared Spectrometer

Wenyue Zhu

Open publisher page 0 citations

Abstract

The steady broad band radiation signal, from the infrared radiation source, passed through a collimator and propogated atmosphere. It was received by the ABB Bomem MR 170 FTIR spectrometer, the detection system. Based on the spectrometer, a set of surface atmospheric infrared transmittance measurement system in open air was constructed. In Hefei area, the system was used to measure actual atmospheric transmittance. Compared the measured results with MODTRAN outputs, the correlation coefficients are bigger than 0.9, but there are great differences at regions from 2500 cm~(-1) to 3000 cm~(-1) and from 4400 cm~(-1) to 4800 cm~(-1). By analyzing the changes of water vapor concentration and the transmittance of 2400 cm~(-1) along with time, the results indicate that the changes of water vapor parameter of local area environment take effect on the transmittance of atmospheric model.

About this research paper

What this paper is about

The steady broad band radiation signal, from the infrared radiation source, passed through a collimator and propogated atmosphere. It was received by the ABB Bomem MR 170 FTIR spectrometer, the detection system. Based on the spectrometer, a set of surface atmospheric infrared transmittance measurement system in open air was constructed. In Hefei area, the system was used to measure actual atmospheric transmittance. Compared the measured results with MODTRAN outputs, the correlation coefficients are bigger than 0.9, but there are great differences at regions from 2500 cm~(-1) to 3000 cm~(-1) and from 4400 cm~(-1) to 4800 cm~(-1). By analyzing the changes of water vapor concentration and the transmittance of 2400 cm~(-1) along with time, the results indicate that the changes of water vapor parameter of local area environment take effect on the transmittance of atmospheric model.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The steady broad band radiation signal, from the infrared radiation source, passed through a collimator and propogated atmosphere. It was received by the ABB Bomem MR 170 FTIR spectrometer, the detection system. Based on the spectrometer, a set of surface atmospheric infrared transmittance measurement system in open air was constructed. In Hefei area, the system was used to measure actual atmospheric transmittance. Compared the measured results with MODTRAN outputs, the correlation coefficients are bigger than 0.9, but there are great differences at regions from 2500 cm~(-1) to 3000 cm~(-1) and from 4400 cm~(-1) to 4800 cm~(-1). By analyzing the changes of water vapor concentration and the transmittance of 2400 cm~(-1) along with time, the results indicate that the changes of water vapor parameter of local area environment take effect on the transmittance of atmospheric model.

Key concepts: MODTRAN, Transmittance, Spectrometer, Infrared, Infrared window, Water vapor, Optics, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Measurements of Atmospheric Transmittance Based on Fourier Transform Infrared Spectrometer — Research Paper | ScholarLens