In order to solve the non-compatible problem between the general monitoring equipments of substation or nonsubstation equipments with substation internal monitoring system of IEC 61850 standard,this paper proposes a new method for the conversion module between Modbus communication protocol and IEC 61850-8-1standard.At first,this paper analyzes the information model of IEC 61850 and of MMS;and by use of the object-oriented technology,an information model of Modbus RTU is built,which establishes the information model mapping relation among Modbus,IEC 61850 and MMS based on the principle of layered semantic correspondence;and then,based on the proposed model,a conversion module between Modbus and IEC 61850-8-1standard is established;finally,an information model for the interval controller is built as an example.Based on the technology like MMS-EASE LITE and so on,this paper achieves the main objective of communication protocol conversion,and realizes the reading and writing service of measurement data such as phase current,which verifies the correctness and feasibility of the proposed method.

About this research paper

What this paper is about

In order to solve the non-compatible problem between the general monitoring equipments of substation or nonsubstation equipments with substation internal monitoring system of IEC 61850 standard,this paper proposes a new method for the conversion module between Modbus communication protocol and IEC 61850-8-1standard.At first,this paper analyzes the information model of IEC 61850 and of MMS;and by use of the object-oriented technology,an information model of Modbus RTU is built,which establishes the information model mapping relation among Modbus,IEC 61850 and MMS based on the principle of layered semantic correspondence;and then,based on the proposed model,a conversion module between Modbus and IEC 61850-8-1standard is established;finally,an information model for the interval controller is built as an example.Based on the technology like MMS-EASE LITE and so on,this paper achieves the main objective of communication protocol conversion,and realizes the reading and writing service of measurement data such as phase current,which verifies the correctness and feasibility of the proposed method.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to solve the non-compatible problem between the general monitoring equipments of substation or nonsubstation equipments with substation internal monitoring system of IEC 61850 standard,this paper proposes a new method for the conversion module between Modbus communication protocol and IEC 61850-8-1standard.At first,this paper analyzes the information model of IEC 61850 and of MMS;and by use of the object-oriented technology,an information model of Modbus RTU is built,which establishes the information model mapping relation among Modbus,IEC 61850 and MMS based on the principle of layered semantic correspondence;and then,based on the proposed model,a conversion module between Modbus and IEC 61850-8-1standard is established;finally,an information model for the interval controller is built as an example.Based on the technology like MMS-EASE LITE and so on,this paper achieves the main objective of communication protocol conversion,and realizes the reading and writing service of measurement data such as phase current,which verifies the correctness and feasibility of the proposed method.

Key concepts: Modbus, IEC 61850, Correctness, Protocol (science), Embedded system, Computer science, Process (computing), Reliability engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
A New Method of Communication Protocol Conversion Process from Modbus to IEC 61850-8-1 and Its Application in Condition Monitoring — Research Paper | ScholarLens