Comparative Study on 3 Methods of Sample Pretreatment for Determination of Harmful Heavy Metals in Chuanxiong Rhizome
Yong Zhang
Abstract
Yong Zhang
Abstract
The methods of①conventional wet acid-digestion,②acid-digestion assisted by microwave heating and③dryashing digestion were used individually for pretreatment of chuanxiong rhizome samples.The contents of Pb,Cu and Cd in each of the sample solutions were determined by GF-AAS,and contents by Hg and As by HG-AFS.As shown by the experimental results,values of recovery of Pb,Cu and Cd found in sample solution obtained by mtthods①and③were in the range of 83.0%to 121.0%,while the values of recovery of Hg and As found in the same solution were much lower.In analyzing sample solution,obtained by method②,higher recovery values ranged from 97.0%-127.0%were found for As,Cu,Cd and Mg,but low recovery value of 51.8%was found for Pb.On the whole,the digestion method①was suitable to be used for determination of Pb by GF-AAS, the method②was suitable for determination of Hg and As by HG-AFS,and the method③was preferred for determination of Cu and Cd by GF-AAS.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The methods of①conventional wet acid-digestion,②acid-digestion assisted by microwave heating and③dryashing digestion were used individually for pretreatment of chuanxiong rhizome samples.The contents of Pb,Cu and Cd in each of the sample solutions were determined by GF-AAS,and contents by Hg and As by HG-AFS.As shown by the experimental results,values of recovery of Pb,Cu and Cd found in sample solution obtained by mtthods①and③were in the range of 83.0%to 121.0%,while the values of recovery of Hg and As found in the same solution were much lower.In analyzing sample solution,obtained by method②,higher recovery values ranged from 97.0%-127.0%were found for As,Cu,Cd and Mg,but low recovery value of 51.8%was found for Pb.On the whole,the digestion method①was suitable to be used for determination of Pb by GF-AAS, the method②was suitable for determination of Hg and As by HG-AFS,and the method③was preferred for determination of Cu and Cd by GF-AAS.
Key concepts: Chemistry, Rhizome, Digestion (alchemy), Chromatography, Microwave digestion, Sample preparation, Detection limit, Traditional medicine