2007•Physical Testing and Chemical AnalysisRequires access

FAAS Determination of Chromium in Aluminum Alloy

Bo Yao

Open publisher page 0 citations

Abstract

Sample was dissolved in hydrochloric acid and hydrogen peroxide,and its chromium content was determined by FAAS.Reductive flame of air-acetylene gas mixture was used in the atomization,and strontium salt was used as inhibitor.Conditions for chemical treatment of sample and operation of the instrument were studied and optimized.Working curve in range of 1.2 mg to 20.0 mg of chromium(Ⅲ) per L of test solution was prepared,having the correlation coefficient of 0.999.In its application to the analysis of 4 standard samples,results obtained were in consistency with the standard values.Values of RSD′s(n=5) and of recovery were found in the ranges of 2.1%-4.2% and 97%-104% respectively.

About this research paper

What this paper is about

Sample was dissolved in hydrochloric acid and hydrogen peroxide,and its chromium content was determined by FAAS.Reductive flame of air-acetylene gas mixture was used in the atomization,and strontium salt was used as inhibitor.Conditions for chemical treatment of sample and operation of the instrument were studied and optimized.Working curve in range of 1.2 mg to 20.0 mg of chromium(Ⅲ) per L of test solution was prepared,having the correlation coefficient of 0.999.In its application to the analysis of 4 standard samples,results obtained were in consistency with the standard values.Values of RSD′s(n=5) and of recovery were found in the ranges of 2.1%-4.2% and 97%-104% respectively.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Sample was dissolved in hydrochloric acid and hydrogen peroxide,and its chromium content was determined by FAAS.Reductive flame of air-acetylene gas mixture was used in the atomization,and strontium salt was used as inhibitor.Conditions for chemical treatment of sample and operation of the instrument were studied and optimized.Working curve in range of 1.2 mg to 20.0 mg of chromium(Ⅲ) per L of test solution was prepared,having the correlation coefficient of 0.999.In its application to the analysis of 4 standard samples,results obtained were in consistency with the standard values.Values of RSD′s(n=5) and of recovery were found in the ranges of 2.1%-4.2% and 97%-104% respectively.

Key concepts: Chromium, Hydrochloric acid, Hydrogen peroxide, Standard addition, Alloy, Chemistry, Analytical Chemistry (journal), Salt (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
FAAS Determination of Chromium in Aluminum Alloy — Research Paper | ScholarLens