2012Gao dianya jishuRequires access

Simulation for Self-extinction Behavior of Secondary Arc in Transmission Lines

Ziming He

Open publisher page 5 citations

Abstract

The self-extinguishing behavior of secondary arcs affects the single-phase re-closure time of transmission lines,so it is important to improve the power system's transmission capacity and reliability.Based on the classic Mayr arc model,the non-linear time-varying arc resistance was introduced to describe the condition of an arc channel,and the arc resistance equations were established.By analyzing the movement characteristics of the secondary arc,the arc's real time length was obtained to iteratively compute the arc resistance.Then an arc resistance criterion was proposed to judge whether arc extinguishes by itself or not according to the law of energy conservation.The equivalent circuit of the arc resistance connected with the system circuit was also put forward to calculate the arc characteristics,and the simulation flow for the self-extinguishing behavior of the secondary arc was further expressed in detail.With the arcing test data at low currents,the parameter estimation was performed for this arc model,and some waveforms of arc voltage,current,resistance and arcing duration were obtained.According to the obtained results,the potential gradient of secondary arc is in a range of 1 500~2 000 V/m.The calculation waveforms are close to the test results,and the arcing duration error is within the permission error of engineering.It is concluded that the presented secondary arc model and its simulation method are reasonable and practicable.

About this research paper

What this paper is about

The self-extinguishing behavior of secondary arcs affects the single-phase re-closure time of transmission lines,so it is important to improve the power system's transmission capacity and reliability.Based on the classic Mayr arc model,the non-linear time-varying arc resistance was introduced to describe the condition of an arc channel,and the arc resistance equations were established.By analyzing the movement characteristics of the secondary arc,the arc's real time length was obtained to iteratively compute the arc resistance.Then an arc resistance criterion was proposed to judge whether arc extinguishes by itself or not according to the law of energy conservation.The equivalent circuit of the arc resistance connected with the system circuit was also put forward to calculate the arc characteristics,and the simulation flow for the self-extinguishing behavior of the secondary arc was further expressed in detail.With the arcing test data at low currents,the parameter estimation was performed for this arc model,and some waveforms of arc voltage,current,resistance and arcing duration were obtained.According to the obtained results,the potential gradient of secondary arc is in a range of 1 500~2 000 V/m.The calculation waveforms are close to the test results,and the arcing duration error is within the permission error of engineering.It is concluded that the presented secondary arc model and its simulation method are reasonable and practicable.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The self-extinguishing behavior of secondary arcs affects the single-phase re-closure time of transmission lines,so it is important to improve the power system's transmission capacity and reliability.Based on the classic Mayr arc model,the non-linear time-varying arc resistance was introduced to describe the condition of an arc channel,and the arc resistance equations were established.By analyzing the movement characteristics of the secondary arc,the arc's real time length was obtained to iteratively compute the arc resistance.Then an arc resistance criterion was proposed to judge whether arc extinguishes by itself or not according to the law of energy conservation.The equivalent circuit of the arc resistance connected with the system circuit was also put forward to calculate the arc characteristics,and the simulation flow for the self-extinguishing behavior of the secondary arc was further expressed in detail.With the arcing test data at low currents,the parameter estimation was performed for this arc model,and some waveforms of arc voltage,current,resistance and arcing duration were obtained.According to the obtained results,the potential gradient of secondary arc is in a range of 1 500~2 000 V/m.The calculation waveforms are close to the test results,and the arcing duration error is within the permission error of engineering.It is concluded that the presented secondary arc model and its simulation method are reasonable and practicable.

Key concepts: Arc (geometry), Electric arc, Waveform, Mechanics, Control theory (sociology), Plasma arc welding, Electrical engineering, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Simulation for Self-extinction Behavior of Secondary Arc in Transmission Lines — Research Paper | ScholarLens