2011•Rock and Mineral AnalysisRequires access

Quantification of Fluorine in Plants by High Temperature Combustion Hydrolysis-Ion Chromatography

Mingyue Hu

Open publisher page 0 citations

Abstract

A new method for the determination of fluorine in plants was developed by high temperature combustion hydrolysis-Ion Chromatography.Chromatographic conditions were selected as Dionex IonPac AS18 separation column(4 mm×250 mm),Dionex IonPac AG18 protect column(4 mm×50 mm),ASRS ULTRA Ⅱ suppressor(4 mm) and conductivity detection.The fluorine ion was absorbed by pure water,which provided the same matrix between the sample solution and the standard solution.The sample solution was analyzed directly by Ion Chromatography with a simple procedure and low cost after filtration.The anions such as Cl-,NO-3,SO2-4,PO3-4,CO2-3,HCO-3 have no interferences with F-,except the acetic acid produced in the process of pyrolysis.In order to eliminate the interference from acetic acid,20 mmol/L NaOH solution was used as equal eluent for higher fluorine sample(xx-xxx μg/g) with the 25 μL sample volume,while for lower fluorine sample(0.x-x μg/g)with the 100 μL sample volume.The new method has wide linear range,high stability and a low detection limit as of 0.5 mg/kg.Four plant reference materials of shrub and tea with higher fluorine contents(xx-xxx μg/g) were studied as the relative error is lower than 10% and the relative standard deviation is lower than 6%.For wheat and rice samples which have lower fluorine content,the recovery by standard addition is 90%-110%.Compared with ion selective electrode and spectrophotometry,Ion Chromatography can be used for samples with a larger range of fluorine concentration,and has the advantages of high automation,easy operation and is environmentally friendly.

About this research paper

What this paper is about

A new method for the determination of fluorine in plants was developed by high temperature combustion hydrolysis-Ion Chromatography.Chromatographic conditions were selected as Dionex IonPac AS18 separation column(4 mm×250 mm),Dionex IonPac AG18 protect column(4 mm×50 mm),ASRS ULTRA Ⅱ suppressor(4 mm) and conductivity detection.The fluorine ion was absorbed by pure water,which provided the same matrix between the sample solution and the standard solution.The sample solution was analyzed directly by Ion Chromatography with a simple procedure and low cost after filtration.The anions such as Cl-,NO-3,SO2-4,PO3-4,CO2-3,HCO-3 have no interferences with F-,except the acetic acid produced in the process of pyrolysis.In order to eliminate the interference from acetic acid,20 mmol/L NaOH solution was used as equal eluent for higher fluorine sample(xx-xxx μg/g) with the 25 μL sample volume,while for lower fluorine sample(0.x-x μg/g)with the 100 μL sample volume.The new method has wide linear range,high stability and a low detection limit as of 0.5 mg/kg.Four plant reference materials of shrub and tea with higher fluorine contents(xx-xxx μg/g) were studied as the relative error is lower than 10% and the relative standard deviation is lower than 6%.For wheat and rice samples which have lower fluorine content,the recovery by standard addition is 90%-110%.Compared with ion selective electrode and spectrophotometry,Ion Chromatography can be used for samples with a larger range of fluorine concentration,and has the advantages of high automation,easy operation and is environmentally friendly.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new method for the determination of fluorine in plants was developed by high temperature combustion hydrolysis-Ion Chromatography.Chromatographic conditions were selected as Dionex IonPac AS18 separation column(4 mm×250 mm),Dionex IonPac AG18 protect column(4 mm×50 mm),ASRS ULTRA Ⅱ suppressor(4 mm) and conductivity detection.The fluorine ion was absorbed by pure water,which provided the same matrix between the sample solution and the standard solution.The sample solution was analyzed directly by Ion Chromatography with a simple procedure and low cost after filtration.The anions such as Cl-,NO-3,SO2-4,PO3-4,CO2-3,HCO-3 have no interferences with F-,except the acetic acid produced in the process of pyrolysis.In order to eliminate the interference from acetic acid,20 mmol/L NaOH solution was used as equal eluent for higher fluorine sample(xx-xxx μg/g) with the 25 μL sample volume,while for lower fluorine sample(0.x-x μg/g)with the 100 μL sample volume.The new method has wide linear range,high stability and a low detection limit as of 0.5 mg/kg.Four plant reference materials of shrub and tea with higher fluorine contents(xx-xxx μg/g) were studied as the relative error is lower than 10% and the relative standard deviation is lower than 6%.For wheat and rice samples which have lower fluorine content,the recovery by standard addition is 90%-110%.Compared with ion selective electrode and spectrophotometry,Ion Chromatography can be used for samples with a larger range of fluorine concentration,and has the advantages of high automation,easy operation and is environmentally friendly.

Key concepts: Ion chromatography, Chemistry, Detection limit, Chromatography, Acetic acid, Analytical Chemistry (journal), Fluorine, Thermal conductivity detector

Related papers

Back to paper searchBrowse research topicsOriginal source
Quantification of Fluorine in Plants by High Temperature Combustion Hydrolysis-Ion Chromatography — Research Paper | ScholarLens