2007•Unpublished venueRequires access

A new fluorimetry system for the determination of trace of benzoic acid in sauce samples

Maotian Xu

Open publisher page 0 citations

Abstract

At the present of Co2+,benzoic acid with weak fluore may react on OH,and then products with intense fluoressence were made.Base on the linear response of the relative fluorescence intensity to the benzoic acid concentration,a novel catalysis kinetics fluorimetry system for the determination of trace of benzoic acid was established with the determination limit of 8.0×10-8 g·mL-1.The linear range was 2.0×10-7-8.0×10-6 g·mL-1.The relative standard deviation(n=9) is 2.4% for 8.0×10-7 g·mL-1 benzoic acid and the system has been applied to the determination of benzoic acid in sauce samples with satisfactory results.

About this research paper

What this paper is about

At the present of Co2+,benzoic acid with weak fluore may react on OH,and then products with intense fluoressence were made.Base on the linear response of the relative fluorescence intensity to the benzoic acid concentration,a novel catalysis kinetics fluorimetry system for the determination of trace of benzoic acid was established with the determination limit of 8.0×10-8 g·mL-1.The linear range was 2.0×10-7-8.0×10-6 g·mL-1.The relative standard deviation(n=9) is 2.4% for 8.0×10-7 g·mL-1 benzoic acid and the system has been applied to the determination of benzoic acid in sauce samples with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

At the present of Co2+,benzoic acid with weak fluore may react on OH,and then products with intense fluoressence were made.Base on the linear response of the relative fluorescence intensity to the benzoic acid concentration,a novel catalysis kinetics fluorimetry system for the determination of trace of benzoic acid was established with the determination limit of 8.0×10-8 g·mL-1.The linear range was 2.0×10-7-8.0×10-6 g·mL-1.The relative standard deviation(n=9) is 2.4% for 8.0×10-7 g·mL-1 benzoic acid and the system has been applied to the determination of benzoic acid in sauce samples with satisfactory results.

Key concepts: Benzoic acid, Chemistry, Detection limit, Fluorescence spectroscopy, Linear range, Fluorescence, Chromatography, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
A new fluorimetry system for the determination of trace of benzoic acid in sauce samples — Research Paper | ScholarLens