2012•Guangdong nongye kexueOpen access

Ultra performance liquid chromatography tandem mass spectrometric for determination of 6 pesticides in raw coffee beans

Chun-Hua Liu

Open full text 0 citations

Abstract

An ultra performance liquid chromatography tandem mass spectrometric method was established for the simultaneous determination the residues of 6 pesticides in raw coffee beans.The samples were processed by ultrasonic extraction with acetonitrile.The analysis was carried out by using electrospray ionization and positive ion monitoring components in the multiple reaction monitoring(MRM) modes,employing the external standard method.Under optimum conditions,the calibration curve was linear in the range of 0.01~ 0.50 mg/L and correlation coefficient r0.99.The limits of quantitation(LOQ) for the six pesticides were 0.001~0.010 mg/kg.The average recoveries of 6 pesticides were 77.7% ~110.0% when the spiked levels were 0.05 mg/kg,0.50 mg/kg and 2.50 mg/kg,with relative standard deviations(RSDs) in the range of 1.3% ~9.9% The method was could be used as liable means for simultaneous quantitative determination.

About this research paper

What this paper is about

An ultra performance liquid chromatography tandem mass spectrometric method was established for the simultaneous determination the residues of 6 pesticides in raw coffee beans.The samples were processed by ultrasonic extraction with acetonitrile.The analysis was carried out by using electrospray ionization and positive ion monitoring components in the multiple reaction monitoring(MRM) modes,employing the external standard method.Under optimum conditions,the calibration curve was linear in the range of 0.01~ 0.50 mg/L and correlation coefficient r0.99.The limits of quantitation(LOQ) for the six pesticides were 0.001~0.010 mg/kg.The average recoveries of 6 pesticides were 77.7% ~110.0% when the spiked levels were 0.05 mg/kg,0.50 mg/kg and 2.50 mg/kg,with relative standard deviations(RSDs) in the range of 1.3% ~9.9% The method was could be used as liable means for simultaneous quantitative determination.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ultra performance liquid chromatography tandem mass spectrometric method was established for the simultaneous determination the residues of 6 pesticides in raw coffee beans.The samples were processed by ultrasonic extraction with acetonitrile.The analysis was carried out by using electrospray ionization and positive ion monitoring components in the multiple reaction monitoring(MRM) modes,employing the external standard method.Under optimum conditions,the calibration curve was linear in the range of 0.01~ 0.50 mg/L and correlation coefficient r0.99.The limits of quantitation(LOQ) for the six pesticides were 0.001~0.010 mg/kg.The average recoveries of 6 pesticides were 77.7% ~110.0% when the spiked levels were 0.05 mg/kg,0.50 mg/kg and 2.50 mg/kg,with relative standard deviations(RSDs) in the range of 1.3% ~9.9% The method was could be used as liable means for simultaneous quantitative determination.

Key concepts: Chromatography, Chemistry, Calibration curve, Pesticide, Electrospray ionization, Detection limit, Selected reaction monitoring, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Ultra performance liquid chromatography tandem mass spectrometric for determination of 6 pesticides in raw coffee beans — Research Paper | ScholarLens