2008•Journal of Chongqing Jianzhu UniversityRequires access

Three-dimensional Large Eddy Simulation of Smoke Flow during Indoor Fire

Xinquan Zhou

Open publisher page 0 citations

Abstract

Indoor fires are quite dangerous,claiming many casualties and resulting in great property loss.Using Computational Fluid Dynamics(CFD),a three-dimensional large eddy simulation model of smoke flow is set up.Through the simulation of smoke flow,the theoretical basis is provided for controlling a fire in multiple rooms,thereby saving people.The results of simulation show that high temperatures and thick smoke exist near the fire,and the probability of combusting other tinder will increase.Moreover,there are close relationships between fire and ventilation.The latter can lower the average temperature and speed up the spread of smoke flow and toxic gases,providing conditions for the further development of indoor fire.Moreover,from both the simulated calculation and physical measurement,it is shown that indoor fires and their temperature distribution and smoke concentration are influenced by the fire power and the room size.The results from calculation and measurement are quite consistent.

About this research paper

What this paper is about

Indoor fires are quite dangerous,claiming many casualties and resulting in great property loss.Using Computational Fluid Dynamics(CFD),a three-dimensional large eddy simulation model of smoke flow is set up.Through the simulation of smoke flow,the theoretical basis is provided for controlling a fire in multiple rooms,thereby saving people.The results of simulation show that high temperatures and thick smoke exist near the fire,and the probability of combusting other tinder will increase.Moreover,there are close relationships between fire and ventilation.The latter can lower the average temperature and speed up the spread of smoke flow and toxic gases,providing conditions for the further development of indoor fire.Moreover,from both the simulated calculation and physical measurement,it is shown that indoor fires and their temperature distribution and smoke concentration are influenced by the fire power and the room size.The results from calculation and measurement are quite consistent.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Indoor fires are quite dangerous,claiming many casualties and resulting in great property loss.Using Computational Fluid Dynamics(CFD),a three-dimensional large eddy simulation model of smoke flow is set up.Through the simulation of smoke flow,the theoretical basis is provided for controlling a fire in multiple rooms,thereby saving people.The results of simulation show that high temperatures and thick smoke exist near the fire,and the probability of combusting other tinder will increase.Moreover,there are close relationships between fire and ventilation.The latter can lower the average temperature and speed up the spread of smoke flow and toxic gases,providing conditions for the further development of indoor fire.Moreover,from both the simulated calculation and physical measurement,it is shown that indoor fires and their temperature distribution and smoke concentration are influenced by the fire power and the room size.The results from calculation and measurement are quite consistent.

Key concepts: Smoke, Large eddy simulation, Environmental science, Computational fluid dynamics, Combustion, Flow (mathematics), Ventilation (architecture), Meteorology

Related papers

Back to paper searchBrowse research topicsOriginal source
Three-dimensional Large Eddy Simulation of Smoke Flow during Indoor Fire — Research Paper | ScholarLens