1999•PubMedRequires access

[Studies on detection of Plasmodium falciparum and Plasmodium vivax in blood samples by multiplex polymerase chain reaction].

S Chen, Lu H, Gao Q, Xinjing Tang

Open publisher page 0 citations

Abstract

AIM: To establish a sensitive and specific PCR-based method to detect Plasmodium falciparum and P. vivax in blood samples in a single amplification reaction. METHODS: Malaria parasite DNA in blood was amplified by the multiplex polymerase chain reaction using two sets of primers derived from the P. f. moderately-repetitive DNA sequence and COIII gene of P.v. RESULTS: A 206-bp product for P. f. and a 370-bp product for P.v. were amplified by multiplex PCR, being able to detect parasitemia level as low as 5 x 10(-7) for P. f. and 1.02 x 10(-6) for P. v. and having no cross-reaction with human leucocyte DNA. A total of 783 blood samples on the filter paper collected from patients attending to malaria clinics in malaria endemic areas were detected. The positive rate of multiplex PCR was 85.8%, the misdiagnosis rate was 0, and the under-diagnosis rate was 0.1%, while these three rates of microscopic examination were 84.9%, 3.1% and 1.0%, respectively. The concordance between the two methods was 95.8%. CONCLUSION: The multiplex PCR method made the malaria detection more sensitive and specific than the microscopic examination and should be suitable for the diagnosis of malaria in mixed endemic areas, large-scale epidemiological studies, follow-up of drug treatment and donor blood screening.

About this research paper

What this paper is about

AIM: To establish a sensitive and specific PCR-based method to detect Plasmodium falciparum and P. vivax in blood samples in a single amplification reaction. METHODS: Malaria parasite DNA in blood was amplified by the multiplex polymerase chain reaction using two sets of primers derived from the P. f. moderately-repetitive DNA sequence and COIII gene of P.v. RESULTS: A 206-bp product for P. f. and a 370-bp product for P.v. were amplified by multiplex PCR, being able to detect parasitemia level as low as 5 x 10(-7) for P. f. and 1.02 x 10(-6) for P. v. and having no cross-reaction with human leucocyte DNA. A total of 783 blood samples on the filter paper collected from patients attending to malaria clinics in malaria endemic areas were detected. The positive rate of multiplex PCR was 85.8%, the misdiagnosis rate was 0, and the under-diagnosis rate was 0.1%, while these three rates of microscopic examination were 84.9%, 3.1% and 1.0%, respectively. The concordance between the two methods was 95.8%. CONCLUSION: The multiplex PCR method made the malaria detection more sensitive and specific than the microscopic examination and should be suitable for the diagnosis of malaria in mixed endemic areas, large-scale epidemiological studies, follow-up of drug treatment and donor blood screening.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM: To establish a sensitive and specific PCR-based method to detect Plasmodium falciparum and P. vivax in blood samples in a single amplification reaction. METHODS: Malaria parasite DNA in blood was amplified by the multiplex polymerase chain reaction using two sets of primers derived from the P. f. moderately-repetitive DNA sequence and COIII gene of P.v. RESULTS: A 206-bp product for P. f. and a 370-bp product for P.v. were amplified by multiplex PCR, being able to detect parasitemia level as low as 5 x 10(-7) for P. f. and 1.02 x 10(-6) for P. v. and having no cross-reaction with human leucocyte DNA. A total of 783 blood samples on the filter paper collected from patients attending to malaria clinics in malaria endemic areas were detected. The positive rate of multiplex PCR was 85.8%, the misdiagnosis rate was 0, and the under-diagnosis rate was 0.1%, while these three rates of microscopic examination were 84.9%, 3.1% and 1.0%, respectively. The concordance between the two methods was 95.8%. CONCLUSION: The multiplex PCR method made the malaria detection more sensitive and specific than the microscopic examination and should be suitable for the diagnosis of malaria in mixed endemic areas, large-scale epidemiological studies, follow-up of drug treatment and donor blood screening.

Key concepts: Plasmodium vivax, Parasitemia, Polymerase chain reaction, Malaria, Plasmodium falciparum, Multiplex polymerase chain reaction, Concordance, Multiplex

Related papers

Back to paper searchBrowse research topicsOriginal source
[Studies on detection of Plasmodium falciparum and Plasmodium vivax in blood samples by multiplex polymerase chain reaction]. — Research Paper | ScholarLens