2007Radiologic PracticeRequires access

Diagnostic Value of 16-Slice Spiral CT Angiography for Intracranial Aneurysm

Xiuping Wang

Open publisher page 0 citations

Abstract

Objective:To evaluvate the 16-slice spiral CT angiography (CTA) in the diagnosis of intracranial aneurysm.Methods:16 patients with clinically suspected intracranial aneurysm were evaluated by 16-slice spiral CTA,8 cases underwent digital subtraction angiography (DSA) simultaneously.Maximal intensity projection (MPR) and volume rendering (VR) images were obtained by reconstruction. Results:Of the 16 patients,17 aneurysms were detected by CTA.One patient had multiple (n=2) and the others had solitary aneurysm.The aneurysms were mainly round or oval in shape (n=15),the others were bean shape (n=2),rosary shape and gourd shape for one case each.The largest one was 18mm and the smallest one was 1.5mm in diameter.Of the 8 patients having DSA,the DSA findings were the same as that of CTA in 7 patients;in one patient,the aneurysm was missed by DSA.Conclusion:16-slice spiral CT angiography is an accurate,rapid and noninvasive method for detecting intracranial aneurysm,especially in the emergency situation,some additional important information can be provided for DSA.

About this research paper

What this paper is about

Objective:To evaluvate the 16-slice spiral CT angiography (CTA) in the diagnosis of intracranial aneurysm.Methods:16 patients with clinically suspected intracranial aneurysm were evaluated by 16-slice spiral CTA,8 cases underwent digital subtraction angiography (DSA) simultaneously.Maximal intensity projection (MPR) and volume rendering (VR) images were obtained by reconstruction. Results:Of the 16 patients,17 aneurysms were detected by CTA.One patient had multiple (n=2) and the others had solitary aneurysm.The aneurysms were mainly round or oval in shape (n=15),the others were bean shape (n=2),rosary shape and gourd shape for one case each.The largest one was 18mm and the smallest one was 1.5mm in diameter.Of the 8 patients having DSA,the DSA findings were the same as that of CTA in 7 patients;in one patient,the aneurysm was missed by DSA.Conclusion:16-slice spiral CT angiography is an accurate,rapid and noninvasive method for detecting intracranial aneurysm,especially in the emergency situation,some additional important information can be provided for DSA.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To evaluvate the 16-slice spiral CT angiography (CTA) in the diagnosis of intracranial aneurysm.Methods:16 patients with clinically suspected intracranial aneurysm were evaluated by 16-slice spiral CTA,8 cases underwent digital subtraction angiography (DSA) simultaneously.Maximal intensity projection (MPR) and volume rendering (VR) images were obtained by reconstruction. Results:Of the 16 patients,17 aneurysms were detected by CTA.One patient had multiple (n=2) and the others had solitary aneurysm.The aneurysms were mainly round or oval in shape (n=15),the others were bean shape (n=2),rosary shape and gourd shape for one case each.The largest one was 18mm and the smallest one was 1.5mm in diameter.Of the 8 patients having DSA,the DSA findings were the same as that of CTA in 7 patients;in one patient,the aneurysm was missed by DSA.Conclusion:16-slice spiral CT angiography is an accurate,rapid and noninvasive method for detecting intracranial aneurysm,especially in the emergency situation,some additional important information can be provided for DSA.

Key concepts: Medicine, Aneurysm, Radiology, Angiography, Digital subtraction angiography, Maximum intensity projection, Volume rendering, Rotational angiography

Related papers

Back to paper searchBrowse research topicsOriginal source
Diagnostic Value of 16-Slice Spiral CT Angiography for Intracranial Aneurysm — Research Paper | ScholarLens