2010•Journal of Shenyang Jianzhu UniversityRequires access

Analysis on the Influence of Indoor Heating Regulation upon Heating Network

Hong Shun Hao

Open publisher page 0 citations

Abstract

In order to understand the influence of heating hydraulic changes upon heating network,based on the theoretical analysis,this paper aims to find out laws of the influence of indoor heating regulation upon heating network.The connected systems can be divided into two parts:direct and indirect.The research is to establish the mathematical expression to show the influence of automatic changes of heating supplying for each unit on the heating network,by applying the fitting function of software Excel.The paper reaches the result that when indoor heating system is directly connected to heating network,the consistency being kept between heating network and indoor heating system with the variable heating supply and variable-speed pumps,meanwhile its flow in heating network is changing;when the indoor system is indirectly connected to heating network,and the volume of indoor heating system is regulated smaller,correspondingly,the return water temperature of indoor heating system changes higher,the difference in temperatures between supply and return water become smaller,and the heating supply of the indoor heating system is reduced,while the flow of the heating network is stable.In conclusion,whatever connected systems are adopted,the influence of pumps of heating system is produced.When system directly connected,variable-speed pumps should be applied in order to adjust to the variable flow system based on the indoor adjustment;while,when system indirectly connected and flow keeping stable,the consistent-speed pumps can be adopted.

About this research paper

What this paper is about

In order to understand the influence of heating hydraulic changes upon heating network,based on the theoretical analysis,this paper aims to find out laws of the influence of indoor heating regulation upon heating network.The connected systems can be divided into two parts:direct and indirect.The research is to establish the mathematical expression to show the influence of automatic changes of heating supplying for each unit on the heating network,by applying the fitting function of software Excel.The paper reaches the result that when indoor heating system is directly connected to heating network,the consistency being kept between heating network and indoor heating system with the variable heating supply and variable-speed pumps,meanwhile its flow in heating network is changing;when the indoor system is indirectly connected to heating network,and the volume of indoor heating system is regulated smaller,correspondingly,the return water temperature of indoor heating system changes higher,the difference in temperatures between supply and return water become smaller,and the heating supply of the indoor heating system is reduced,while the flow of the heating network is stable.In conclusion,whatever connected systems are adopted,the influence of pumps of heating system is produced.When system directly connected,variable-speed pumps should be applied in order to adjust to the variable flow system based on the indoor adjustment;while,when system indirectly connected and flow keeping stable,the consistent-speed pumps can be adopted.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to understand the influence of heating hydraulic changes upon heating network,based on the theoretical analysis,this paper aims to find out laws of the influence of indoor heating regulation upon heating network.The connected systems can be divided into two parts:direct and indirect.The research is to establish the mathematical expression to show the influence of automatic changes of heating supplying for each unit on the heating network,by applying the fitting function of software Excel.The paper reaches the result that when indoor heating system is directly connected to heating network,the consistency being kept between heating network and indoor heating system with the variable heating supply and variable-speed pumps,meanwhile its flow in heating network is changing;when the indoor system is indirectly connected to heating network,and the volume of indoor heating system is regulated smaller,correspondingly,the return water temperature of indoor heating system changes higher,the difference in temperatures between supply and return water become smaller,and the heating supply of the indoor heating system is reduced,while the flow of the heating network is stable.In conclusion,whatever connected systems are adopted,the influence of pumps of heating system is produced.When system directly connected,variable-speed pumps should be applied in order to adjust to the variable flow system based on the indoor adjustment;while,when system indirectly connected and flow keeping stable,the consistent-speed pumps can be adopted.

Key concepts: Heating system, Variable (mathematics), Heating element, Consistency (knowledge bases), Flow (mathematics), Environmental science, Process engineering, Automotive engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis on the Influence of Indoor Heating Regulation upon Heating Network — Research Paper | ScholarLens