2002Unpublished venueRequires access

Accuracy of target localization of linac radiosurgery system

Wang Yun

Open publisher page 0 citations

Abstract

Objective: To study the accuracy of SRS200 linac radiosurgery system in our hospital. Methods: The CT localization accuracy of linac radiosurgery system was measured by markers in skull phantom, and the accuracy of isocenter subsystem and common error by film method. Results: The accuracy of CT localization of BRW headring was 0.65 ?mm and maximum error was 1.09?mm. The accuracy of SRS200 isocenter subsystem was 0.19?mm. The common accuracy of linac radiosurgery system was 0.68?mm mathematically and 1.43?mm actually. Conclusion: The accuracy of this linac radiosurgery system has come up to the standard of quality control of stereotactic radiosurgery.

About this research paper

What this paper is about

Objective: To study the accuracy of SRS200 linac radiosurgery system in our hospital. Methods: The CT localization accuracy of linac radiosurgery system was measured by markers in skull phantom, and the accuracy of isocenter subsystem and common error by film method. Results: The accuracy of CT localization of BRW headring was 0.65 ?mm and maximum error was 1.09?mm. The accuracy of SRS200 isocenter subsystem was 0.19?mm. The common accuracy of linac radiosurgery system was 0.68?mm mathematically and 1.43?mm actually. Conclusion: The accuracy of this linac radiosurgery system has come up to the standard of quality control of stereotactic radiosurgery.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To study the accuracy of SRS200 linac radiosurgery system in our hospital. Methods: The CT localization accuracy of linac radiosurgery system was measured by markers in skull phantom, and the accuracy of isocenter subsystem and common error by film method. Results: The accuracy of CT localization of BRW headring was 0.65 ?mm and maximum error was 1.09?mm. The accuracy of SRS200 isocenter subsystem was 0.19?mm. The common accuracy of linac radiosurgery system was 0.68?mm mathematically and 1.43?mm actually. Conclusion: The accuracy of this linac radiosurgery system has come up to the standard of quality control of stereotactic radiosurgery.

Key concepts: Isocenter, Radiosurgery, Linear particle accelerator, Imaging phantom, Nuclear medicine, Medicine, Beam (structure), Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Accuracy of target localization of linac radiosurgery system — Research Paper | ScholarLens