2007•Unpublished venueRequires access

Clinical value of CT perfusion in the differentia; diagnosis of parotid gland tumors

Fan Weijun, Li Wan, Sun Yat-sen

Open publisher page 0 citations

Abstract

Objective To explore the usefulness of CT perfusion imaging in quantitatively judging the blood patterns of the benign tumors and the malignancies of the parotid,and to evaluate its clinical value in differentiating benign tumors from malignant tumors of the parotid.Methods Fifty-three patients were included in this study (35 with benign tumors and 18 with malignant tumors).All the tumors were confirmed histopathologieally and examined with CT perfusion before operations.The parameters of CT perfusion were obtained by using PHILIPS perfusion software,including time-density curve (TDC),perfusion (ml· 100g~(-1)·min~(-1)),peak height (PH: HU),time to peak (TTP: s),blood volume (BV:ml·100g~(-1) and mean transit time (MTT: s). Wilcoxon signed-rank test for paired data were used to determine the statistical differences of parameters between the benign and malignant tumors.Rsults The median and quartile range of Perfusion,PH,TTP,BV,MTT were 73.5ml·100g~(-1)·min~(-1)(18.7 113.3) 34.5 HU,(17.7,53.1),20.0 s,(13.6,34.4),38.5ml·100g~(-1),(29.1,63.3),7.6 s,(4.5,28.7) respectively in benign tumors,versus 135.9ml·100g~(-1)·min~(-1),(101.4,195.2 ),49.1 HU,(32.7, 59.4),12.9 s,(11.3,14.6),67.5ml·100g~(-1),(52.4,109.5),6.0 s,(5.1,7.6)in malignant tumors. Except for PH,MTT,the difference of perfusion,TIP and BV between benign and malignant tumors were statistically significant(P0.05 ),The difference of TDC among the Warthin's tumor,other benign tumors, and malignant tumors was also statistically significant (P0.05).Conclusions On the basis of this study, the parameters of CT perfusion,BF,BV and TDC were valuable in differentiating benign and malignant tumors of the parotid gland.

About this research paper

What this paper is about

Objective To explore the usefulness of CT perfusion imaging in quantitatively judging the blood patterns of the benign tumors and the malignancies of the parotid,and to evaluate its clinical value in differentiating benign tumors from malignant tumors of the parotid.Methods Fifty-three patients were included in this study (35 with benign tumors and 18 with malignant tumors).All the tumors were confirmed histopathologieally and examined with CT perfusion before operations.The parameters of CT perfusion were obtained by using PHILIPS perfusion software,including time-density curve (TDC),perfusion (ml· 100g~(-1)·min~(-1)),peak height (PH: HU),time to peak (TTP: s),blood volume (BV:ml·100g~(-1) and mean transit time (MTT: s). Wilcoxon signed-rank test for paired data were used to determine the statistical differences of parameters between the benign and malignant tumors.Rsults The median and quartile range of Perfusion,PH,TTP,BV,MTT were 73.5ml·100g~(-1)·min~(-1)(18.7 113.3) 34.5 HU,(17.7,53.1),20.0 s,(13.6,34.4),38.5ml·100g~(-1),(29.1,63.3),7.6 s,(4.5,28.7) respectively in benign tumors,versus 135.9ml·100g~(-1)·min~(-1),(101.4,195.2 ),49.1 HU,(32.7, 59.4),12.9 s,(11.3,14.6),67.5ml·100g~(-1),(52.4,109.5),6.0 s,(5.1,7.6)in malignant tumors. Except for PH,MTT,the difference of perfusion,TIP and BV between benign and malignant tumors were statistically significant(P0.05 ),The difference of TDC among the Warthin's tumor,other benign tumors, and malignant tumors was also statistically significant (P0.05).Conclusions On the basis of this study, the parameters of CT perfusion,BF,BV and TDC were valuable in differentiating benign and malignant tumors of the parotid gland.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the usefulness of CT perfusion imaging in quantitatively judging the blood patterns of the benign tumors and the malignancies of the parotid,and to evaluate its clinical value in differentiating benign tumors from malignant tumors of the parotid.Methods Fifty-three patients were included in this study (35 with benign tumors and 18 with malignant tumors).All the tumors were confirmed histopathologieally and examined with CT perfusion before operations.The parameters of CT perfusion were obtained by using PHILIPS perfusion software,including time-density curve (TDC),perfusion (ml· 100g~(-1)·min~(-1)),peak height (PH: HU),time to peak (TTP: s),blood volume (BV:ml·100g~(-1) and mean transit time (MTT: s). Wilcoxon signed-rank test for paired data were used to determine the statistical differences of parameters between the benign and malignant tumors.Rsults The median and quartile range of Perfusion,PH,TTP,BV,MTT were 73.5ml·100g~(-1)·min~(-1)(18.7 113.3) 34.5 HU,(17.7,53.1),20.0 s,(13.6,34.4),38.5ml·100g~(-1),(29.1,63.3),7.6 s,(4.5,28.7) respectively in benign tumors,versus 135.9ml·100g~(-1)·min~(-1),(101.4,195.2 ),49.1 HU,(32.7, 59.4),12.9 s,(11.3,14.6),67.5ml·100g~(-1),(52.4,109.5),6.0 s,(5.1,7.6)in malignant tumors. Except for PH,MTT,the difference of perfusion,TIP and BV between benign and malignant tumors were statistically significant(P0.05 ),The difference of TDC among the Warthin's tumor,other benign tumors, and malignant tumors was also statistically significant (P0.05).Conclusions On the basis of this study, the parameters of CT perfusion,BF,BV and TDC were valuable in differentiating benign and malignant tumors of the parotid gland.

Key concepts: Medicine, Perfusion, Nuclear medicine, Perfusion scanning, Quartile, Radiology, Blood volume, Pathology

Related papers

Back to paper searchBrowse research topicsOriginal source
Clinical value of CT perfusion in the differentia; diagnosis of parotid gland tumors — Research Paper | ScholarLens