Abstract

In digital substations with electronic transformers,the key for implementation of line differential protection is the synchronization of electrical quantities at both two sides. A new method is proposed to solve the problem. First,merging unit (MU ) and protection device of digital stations are synchronized by unified clock source. Then data of ac quantities used for protection are calculated with interpolation method. Finally,protection devices synchronization in substations at two sides are completed by sampling time adjustment method. And the synchronization of electrical quantities at both sides is achieved.

About this research paper

What this paper is about

In digital substations with electronic transformers,the key for implementation of line differential protection is the synchronization of electrical quantities at both two sides. A new method is proposed to solve the problem. First,merging unit (MU ) and protection device of digital stations are synchronized by unified clock source. Then data of ac quantities used for protection are calculated with interpolation method. Finally,protection devices synchronization in substations at two sides are completed by sampling time adjustment method. And the synchronization of electrical quantities at both sides is achieved.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In digital substations with electronic transformers,the key for implementation of line differential protection is the synchronization of electrical quantities at both two sides. A new method is proposed to solve the problem. First,merging unit (MU ) and protection device of digital stations are synchronized by unified clock source. Then data of ac quantities used for protection are calculated with interpolation method. Finally,protection devices synchronization in substations at two sides are completed by sampling time adjustment method. And the synchronization of electrical quantities at both sides is achieved.

Key concepts: Differential protection, Synchronization (alternating current), Data synchronization, Line (geometry), Transformer, Computer science, Electronic engineering, Differential (mechanical device)

Related papers

Back to paper searchBrowse research topicsOriginal source
A New Synchronization Method of Optical Fiber Line Differential Protection for Digital Substation — Research Paper | ScholarLens