Analysis on Measures of Improving Lightning Withstand Level of 10kV Overhead Insulation-covered Conductors

He Jian

Open publisher page 0 citations

Abstract

The lightning parameters of 2001~2007 in Chongqing Jiangbei District were collected by lightning location system(LLS) and sta-tistically analyzed.Simulation model established by electromagnetic transient program(EMTP) .Analyze and compare the effect of improving lightning withstand level by line surge arrester in different programs.The influence of impulse grounding resistance of towers and the locations where lightning stroked are analyzed.The results showed that installing the line surge arresters can effectively improve the lightning withstand level of transmission line.The measures, such as reducing grounding resistance of towers, installing metal oxide surge arrester with series gap and arc-protection hardware with stabs, can effectively reduce the rate of flashover and lightning-caused breaking of covered conductors of 10kV distribution lines.

About this research paper

What this paper is about

The lightning parameters of 2001~2007 in Chongqing Jiangbei District were collected by lightning location system(LLS) and sta-tistically analyzed.Simulation model established by electromagnetic transient program(EMTP) .Analyze and compare the effect of improving lightning withstand level by line surge arrester in different programs.The influence of impulse grounding resistance of towers and the locations where lightning stroked are analyzed.The results showed that installing the line surge arresters can effectively improve the lightning withstand level of transmission line.The measures, such as reducing grounding resistance of towers, installing metal oxide surge arrester with series gap and arc-protection hardware with stabs, can effectively reduce the rate of flashover and lightning-caused breaking of covered conductors of 10kV distribution lines.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The lightning parameters of 2001~2007 in Chongqing Jiangbei District were collected by lightning location system(LLS) and sta-tistically analyzed.Simulation model established by electromagnetic transient program(EMTP) .Analyze and compare the effect of improving lightning withstand level by line surge arrester in different programs.The influence of impulse grounding resistance of towers and the locations where lightning stroked are analyzed.The results showed that installing the line surge arresters can effectively improve the lightning withstand level of transmission line.The measures, such as reducing grounding resistance of towers, installing metal oxide surge arrester with series gap and arc-protection hardware with stabs, can effectively reduce the rate of flashover and lightning-caused breaking of covered conductors of 10kV distribution lines.

Key concepts: Lightning arrester, Surge arrester, Installation, Arc flash, Engineering, Ground, Overhead line, Emtp

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis on Measures of Improving Lightning Withstand Level of 10kV Overhead Insulation-covered Conductors — Research Paper | ScholarLens