2015Packaging and Food MachineryRequires access

Determination of Lead and Cadmium in Longting Plums by Microwave Digestion-graphite Furnace Atomic Absorption Spectrometry

Cao Fen

Open publisher page 0 citations

Abstract

A method was developed for determination of lead and cadmium in Longting plumsby microwave digestion-GFAAS,the sample was digested with HNO3- H2O2,and the contents were determined by calibration curve method. It was showed that the linear range of lead andcadmium at 0. 0 ~ 5. 0 ng / m L and 0. 0 ~2. 5 ng / m L,the correlation coefficients were 0. 99969 and0. 99989. The average recovery of lead was 98. 2%,and the average recovery of cadmium was 97. 9%. RSD( n = 6) of lead and cadmium were 2. 03% and2. 18%. The detection limits of lead and cadmium were 0. 002 mg / kg and 0. 0003 mg / kg. The result showed that this method was simple and fast,andcould determine the content of lead and cadmium exactly in Longting plums.

About this research paper

What this paper is about

A method was developed for determination of lead and cadmium in Longting plumsby microwave digestion-GFAAS,the sample was digested with HNO3- H2O2,and the contents were determined by calibration curve method. It was showed that the linear range of lead andcadmium at 0. 0 ~ 5. 0 ng / m L and 0. 0 ~2. 5 ng / m L,the correlation coefficients were 0. 99969 and0. 99989. The average recovery of lead was 98. 2%,and the average recovery of cadmium was 97. 9%. RSD( n = 6) of lead and cadmium were 2. 03% and2. 18%. The detection limits of lead and cadmium were 0. 002 mg / kg and 0. 0003 mg / kg. The result showed that this method was simple and fast,andcould determine the content of lead and cadmium exactly in Longting plums.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was developed for determination of lead and cadmium in Longting plumsby microwave digestion-GFAAS,the sample was digested with HNO3- H2O2,and the contents were determined by calibration curve method. It was showed that the linear range of lead andcadmium at 0. 0 ~ 5. 0 ng / m L and 0. 0 ~2. 5 ng / m L,the correlation coefficients were 0. 99969 and0. 99989. The average recovery of lead was 98. 2%,and the average recovery of cadmium was 97. 9%. RSD( n = 6) of lead and cadmium were 2. 03% and2. 18%. The detection limits of lead and cadmium were 0. 002 mg / kg and 0. 0003 mg / kg. The result showed that this method was simple and fast,andcould determine the content of lead and cadmium exactly in Longting plums.

Key concepts: Cadmium, Graphite furnace atomic absorption, Microwave digestion, Calibration curve, Chemistry, Detection limit, Analytical Chemistry (journal), Atomic absorption spectroscopy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Lead and Cadmium in Longting Plums by Microwave Digestion-graphite Furnace Atomic Absorption Spectrometry — Research Paper | ScholarLens