Application of Low Dose Photography in Pelvic Digital Radiography

Jiang Zhen

Open publisher page 0 citations

Abstract

Objective To study the value of low dose photography in pelvis digital radiography with AEC(automatic exposure control).Materials and Methods 50 patients with pelvic trauma were performed with anterior-posterior pelvic radiography with conventional dose for the first diagnosis,and with low dose for the follow-up.The difference of radiant exposure value and the dose area product (DAP) between the two dose groups of radiography was analyzed.The imaging quality of the two dose groups was also evaluated in term of the subjective grading conducted by a radiologist and a technician according to the European Economic Community Standard.Results The radiant exposure value of the low dose group was 2.48±1.20,which was significantly lower than that of the conventional group (14.78±1.20) (t=13.69,P0.01),similarly,the DAP of the low dose group was 3.63±1.79,which was also significantly lower in comparison with that of the conventional group (10.23±1.69) (t=9.22,P0.01).However,no significant difference in imaging quality was detected between the two dose groups (Manne Whitney U=1175.00,P=0.34).Conclusion The low dose pelvis radiography could reduce markedly the exposure dose,whereas almostly impact the imaging quality.

About this research paper

What this paper is about

Objective To study the value of low dose photography in pelvis digital radiography with AEC(automatic exposure control).Materials and Methods 50 patients with pelvic trauma were performed with anterior-posterior pelvic radiography with conventional dose for the first diagnosis,and with low dose for the follow-up.The difference of radiant exposure value and the dose area product (DAP) between the two dose groups of radiography was analyzed.The imaging quality of the two dose groups was also evaluated in term of the subjective grading conducted by a radiologist and a technician according to the European Economic Community Standard.Results The radiant exposure value of the low dose group was 2.48±1.20,which was significantly lower than that of the conventional group (14.78±1.20) (t=13.69,P0.01),similarly,the DAP of the low dose group was 3.63±1.79,which was also significantly lower in comparison with that of the conventional group (10.23±1.69) (t=9.22,P0.01).However,no significant difference in imaging quality was detected between the two dose groups (Manne Whitney U=1175.00,P=0.34).Conclusion The low dose pelvis radiography could reduce markedly the exposure dose,whereas almostly impact the imaging quality.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To study the value of low dose photography in pelvis digital radiography with AEC(automatic exposure control).Materials and Methods 50 patients with pelvic trauma were performed with anterior-posterior pelvic radiography with conventional dose for the first diagnosis,and with low dose for the follow-up.The difference of radiant exposure value and the dose area product (DAP) between the two dose groups of radiography was analyzed.The imaging quality of the two dose groups was also evaluated in term of the subjective grading conducted by a radiologist and a technician according to the European Economic Community Standard.Results The radiant exposure value of the low dose group was 2.48±1.20,which was significantly lower than that of the conventional group (14.78±1.20) (t=13.69,P0.01),similarly,the DAP of the low dose group was 3.63±1.79,which was also significantly lower in comparison with that of the conventional group (10.23±1.69) (t=9.22,P0.01).However,no significant difference in imaging quality was detected between the two dose groups (Manne Whitney U=1175.00,P=0.34).Conclusion The low dose pelvis radiography could reduce markedly the exposure dose,whereas almostly impact the imaging quality.

Key concepts: Medicine, Digital radiography, Radiography, Pelvis, Nuclear medicine, Radiation dose, Conventional radiography, Radiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Application of Low Dose Photography in Pelvic Digital Radiography — Research Paper | ScholarLens