A method for determination of impurity elements in nickel lanthanum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was proposed.All the influencing factors on spectrum measuring were investigated.The sample was decomposed by mixed acid(HCL,HNO3),the experiment of instrument parameters,selection of analysis lines were studied,the optimal determination conditions of instrument were obtained,the analytical lines were Si 251.611 nm,Mn 257.610 nm,Mg285.213 nm,Cu 324.752 nm,Zn 213.857 nm,Cd 214.440 nm,Pb 220.353 nm,Zr 343.823 nm,respectively,the effect of matrix and coexist elements on the determination was carried out.The matrix effect was corrected by matrix matching.The detection limits were 0.0003-0.015μg/ml,the recovery rates were from 80%to 108%,the RSD were less than 8%.

About this research paper

What this paper is about

A method for determination of impurity elements in nickel lanthanum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was proposed.All the influencing factors on spectrum measuring were investigated.The sample was decomposed by mixed acid(HCL,HNO3),the experiment of instrument parameters,selection of analysis lines were studied,the optimal determination conditions of instrument were obtained,the analytical lines were Si 251.611 nm,Mn 257.610 nm,Mg285.213 nm,Cu 324.752 nm,Zn 213.857 nm,Cd 214.440 nm,Pb 220.353 nm,Zr 343.823 nm,respectively,the effect of matrix and coexist elements on the determination was carried out.The matrix effect was corrected by matrix matching.The detection limits were 0.0003-0.015μg/ml,the recovery rates were from 80%to 108%,the RSD were less than 8%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of impurity elements in nickel lanthanum alloy by inductively coupled plasma atomic emission spectrometry(ICP-AES)was proposed.All the influencing factors on spectrum measuring were investigated.The sample was decomposed by mixed acid(HCL,HNO3),the experiment of instrument parameters,selection of analysis lines were studied,the optimal determination conditions of instrument were obtained,the analytical lines were Si 251.611 nm,Mn 257.610 nm,Mg285.213 nm,Cu 324.752 nm,Zn 213.857 nm,Cd 214.440 nm,Pb 220.353 nm,Zr 343.823 nm,respectively,the effect of matrix and coexist elements on the determination was carried out.The matrix effect was corrected by matrix matching.The detection limits were 0.0003-0.015μg/ml,the recovery rates were from 80%to 108%,the RSD were less than 8%.

Key concepts: Lanthanum, Inductively coupled plasma, Analytical Chemistry (journal), Impurity, Nickel, Inductively coupled plasma atomic emission spectroscopy, Matrix (chemical analysis), Alloy

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of impurity elements Si,Mn,Mg,Cu,Zn,Cd,Pb,and Zr in nickel lanthanum alloy by inductively coupled plasma atomic emission spectrometry — Research Paper | ScholarLens