2009Laboratory MedicineRequires access

Research on reference range of venous red blood cell measured by automated haematology analyzer for healthy adults in Shangri-la county of Yunnan province

Wenjun Cao

Open publisher page 0 citations

Abstract

Objective To establish the reference range of venous red blood cell(RBC) measured by automated haematology analyzer for healthy adults in Shangri-la county of Diqing Tibetan Autonomous Prefecture,Yunnan province.Methods 412 healthy adults were randomly chosen from the above-mentioned area.Their venous blood samples were collected for routine analysis by Beckman-Coulter AC.T diff 2 automated haematology analyzer.The results were analysed statistically and compared with reference materials.Results The ranges of RBC were 4.31-6.54×1012/L in males and 4.15-5.66×1012/L in females.The hematocrits(HCT) were 37.9-61.3% in males and 37.6-50.7% in females.The ranges of hemoglobin(Hb) were 134-202 g/L in males and 124-174 g/L in females.The ranges of mean corpuscular hemoglobin(MCH) were 25.3-36.0 pg in males and 26.2-34.3 pg in females.The ranges of mean corpuscular hemoglobin concentration(MCHC) were 306-379 g/L in males and 312-367 g /L in females.The ranges of mean corpuscular volume(MCV) were 76.5-102.6 fl in males and 79.0-99.3 fl in females.Comparing with reference results,RBC,Hb,and HCT increased remarkably(P0.05).There was statistical difference for MCV and MCHC(P0.05),and no statistical difference for MCH(P0.05).Conclusions According to the clinical observation by now,the reference range of venous RBC for healthy adults of Shangri-la county can be applied to medical health practice for clinical diagnosis,treatment and health-examination.

About this research paper

What this paper is about

Objective To establish the reference range of venous red blood cell(RBC) measured by automated haematology analyzer for healthy adults in Shangri-la county of Diqing Tibetan Autonomous Prefecture,Yunnan province.Methods 412 healthy adults were randomly chosen from the above-mentioned area.Their venous blood samples were collected for routine analysis by Beckman-Coulter AC.T diff 2 automated haematology analyzer.The results were analysed statistically and compared with reference materials.Results The ranges of RBC were 4.31-6.54×1012/L in males and 4.15-5.66×1012/L in females.The hematocrits(HCT) were 37.9-61.3% in males and 37.6-50.7% in females.The ranges of hemoglobin(Hb) were 134-202 g/L in males and 124-174 g/L in females.The ranges of mean corpuscular hemoglobin(MCH) were 25.3-36.0 pg in males and 26.2-34.3 pg in females.The ranges of mean corpuscular hemoglobin concentration(MCHC) were 306-379 g/L in males and 312-367 g /L in females.The ranges of mean corpuscular volume(MCV) were 76.5-102.6 fl in males and 79.0-99.3 fl in females.Comparing with reference results,RBC,Hb,and HCT increased remarkably(P0.05).There was statistical difference for MCV and MCHC(P0.05),and no statistical difference for MCH(P0.05).Conclusions According to the clinical observation by now,the reference range of venous RBC for healthy adults of Shangri-la county can be applied to medical health practice for clinical diagnosis,treatment and health-examination.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the reference range of venous red blood cell(RBC) measured by automated haematology analyzer for healthy adults in Shangri-la county of Diqing Tibetan Autonomous Prefecture,Yunnan province.Methods 412 healthy adults were randomly chosen from the above-mentioned area.Their venous blood samples were collected for routine analysis by Beckman-Coulter AC.T diff 2 automated haematology analyzer.The results were analysed statistically and compared with reference materials.Results The ranges of RBC were 4.31-6.54×1012/L in males and 4.15-5.66×1012/L in females.The hematocrits(HCT) were 37.9-61.3% in males and 37.6-50.7% in females.The ranges of hemoglobin(Hb) were 134-202 g/L in males and 124-174 g/L in females.The ranges of mean corpuscular hemoglobin(MCH) were 25.3-36.0 pg in males and 26.2-34.3 pg in females.The ranges of mean corpuscular hemoglobin concentration(MCHC) were 306-379 g/L in males and 312-367 g /L in females.The ranges of mean corpuscular volume(MCV) were 76.5-102.6 fl in males and 79.0-99.3 fl in females.Comparing with reference results,RBC,Hb,and HCT increased remarkably(P0.05).There was statistical difference for MCV and MCHC(P0.05),and no statistical difference for MCH(P0.05).Conclusions According to the clinical observation by now,the reference range of venous RBC for healthy adults of Shangri-la county can be applied to medical health practice for clinical diagnosis,treatment and health-examination.

Key concepts: Mean corpuscular volume, Mean corpuscular hemoglobin concentration, Mean corpuscular hemoglobin, Reference range, Hematology analyzer, Hemoglobin, Medicine, Venous blood

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on reference range of venous red blood cell measured by automated haematology analyzer for healthy adults in Shangri-la county of Yunnan province — Research Paper | ScholarLens