2014Biaoji mianyi fenxi yu linchuangRequires access

Performance Verification of Electrochemiluminescence Immunoassay System in the Detection of T_3 and T_4

Zhuang Yue-pen

Open publisher page 0 citations

Abstract

Objective To verify the analytical performance of Roche Cobas E601 automatic electrochemiluminescence immunoassay(ECLIA) system in the detection of triiodothyronine(T_3) and thyronine(T_4) and to explore a simple verification strategy of the matching detection system.Methods By analysis of internal quality control data and test according to Clinical and Laboratory Standards Institute(CLSI) related guideline,the precision,trueness,reportable range and reference interval of Roche Cobas E601 ECLIA system in the detection of T_3 and T_4were verified.The results were compared with manufacturer's claims or acceptable quality standards.Results The within-run precision coefficients of variation(CV) of T_3 and T_4 was 1.29% -6.15% , 1/4Tea(CLIA' 88).The within-laboratory precision CV was 4.02% - 5.65% , 1/3Tea(CLIA'88).The system error(SE% ) of external quality assessment control samples was-1.38% --4.18% , 1/2Tea(CLIA' 88).The reportable range was comparable with the declaration of the manufacturer.The verification results of reference interval of T_3 and T_4were in line with manufacturer reference interval.Conclusion The main analytical performance of T_3 and T_4 measurement by Roche Cobas E601 automatic ECLIA system is consistent with acceptable quality standards,and the used verification projects are simple,feasible and practical.

About this research paper

What this paper is about

Objective To verify the analytical performance of Roche Cobas E601 automatic electrochemiluminescence immunoassay(ECLIA) system in the detection of triiodothyronine(T_3) and thyronine(T_4) and to explore a simple verification strategy of the matching detection system.Methods By analysis of internal quality control data and test according to Clinical and Laboratory Standards Institute(CLSI) related guideline,the precision,trueness,reportable range and reference interval of Roche Cobas E601 ECLIA system in the detection of T_3 and T_4were verified.The results were compared with manufacturer's claims or acceptable quality standards.Results The within-run precision coefficients of variation(CV) of T_3 and T_4 was 1.29% -6.15% , 1/4Tea(CLIA' 88).The within-laboratory precision CV was 4.02% - 5.65% , 1/3Tea(CLIA'88).The system error(SE% ) of external quality assessment control samples was-1.38% --4.18% , 1/2Tea(CLIA' 88).The reportable range was comparable with the declaration of the manufacturer.The verification results of reference interval of T_3 and T_4were in line with manufacturer reference interval.Conclusion The main analytical performance of T_3 and T_4 measurement by Roche Cobas E601 automatic ECLIA system is consistent with acceptable quality standards,and the used verification projects are simple,feasible and practical.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To verify the analytical performance of Roche Cobas E601 automatic electrochemiluminescence immunoassay(ECLIA) system in the detection of triiodothyronine(T_3) and thyronine(T_4) and to explore a simple verification strategy of the matching detection system.Methods By analysis of internal quality control data and test according to Clinical and Laboratory Standards Institute(CLSI) related guideline,the precision,trueness,reportable range and reference interval of Roche Cobas E601 ECLIA system in the detection of T_3 and T_4were verified.The results were compared with manufacturer's claims or acceptable quality standards.Results The within-run precision coefficients of variation(CV) of T_3 and T_4 was 1.29% -6.15% , 1/4Tea(CLIA' 88).The within-laboratory precision CV was 4.02% - 5.65% , 1/3Tea(CLIA'88).The system error(SE% ) of external quality assessment control samples was-1.38% --4.18% , 1/2Tea(CLIA' 88).The reportable range was comparable with the declaration of the manufacturer.The verification results of reference interval of T_3 and T_4were in line with manufacturer reference interval.Conclusion The main analytical performance of T_3 and T_4 measurement by Roche Cobas E601 automatic ECLIA system is consistent with acceptable quality standards,and the used verification projects are simple,feasible and practical.

Key concepts: Electrochemiluminescence, Medicine, External quality assessment, Roche Diagnostics, Statistics, Detection limit, Mathematics, Internal medicine