2012Northwest HydropowerRequires access

Protection Design of Main Transformer,220KV Shuntang Substation Stage I

Ma Qin

Open publisher page 0 citations

Abstract

In combination with regulations and specification,principle of dual-protection arrangement for substation is briefed,primary arrangement scheme for main transformer protection of 220 kV Shuntang substation Stage Ⅰ,Xinjiang Tuokexun wind farm project is provided,design concept and relevant technical specifications for main protection arrangements such as differential protection,overcurrent protection and failure protection,etc are described.Finally,schemes for type selection and panel combination of the substation are provided.

About this research paper

What this paper is about

In combination with regulations and specification,principle of dual-protection arrangement for substation is briefed,primary arrangement scheme for main transformer protection of 220 kV Shuntang substation Stage Ⅰ,Xinjiang Tuokexun wind farm project is provided,design concept and relevant technical specifications for main protection arrangements such as differential protection,overcurrent protection and failure protection,etc are described.Finally,schemes for type selection and panel combination of the substation are provided.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In combination with regulations and specification,principle of dual-protection arrangement for substation is briefed,primary arrangement scheme for main transformer protection of 220 kV Shuntang substation Stage Ⅰ,Xinjiang Tuokexun wind farm project is provided,design concept and relevant technical specifications for main protection arrangements such as differential protection,overcurrent protection and failure protection,etc are described.Finally,schemes for type selection and panel combination of the substation are provided.

Key concepts: Engineering, Transformer, Overcurrent, Differential protection, Reliability engineering, Electrical engineering, Voltage

Related papers

Back to paper searchBrowse research topicsOriginal source
Protection Design of Main Transformer,220KV Shuntang Substation Stage I — Research Paper | ScholarLens