2008Jiliang xuebaoRequires access

Experiments on the Flow Characteristics of Gas Vortex Flowmeter under Different Medium Densities

Li-xiao QI

Open publisher page 1 citations

Abstract

To investigate the flow characteristics including meter coefficient,linearity,uncertainty and lower flow limit of the vortex flowmeter under different medium densities,tremendous experiments are performed on the gas flow calibration facility based on barotropic venturi nozzles.The flowmeter with a diameter of 50 mm was calibrated at the air density of 2.774 kg/m~3,3.619 kg/m~3,4.782 kg/m~3 and 5.987 kg/m~3 respectively by adjusting the pressure in conduits from 0.23 MPa to 0.5 MPa.The results demonstrate that the maximum relative error of meter coefficient under different densities is 0.405%,which verifies that the medium density has little influence on the meter coefficient of vortex flowmeter.It is also found that the lower flow limit extends downward with the increase of medium density.And the reason for this phenomenon is discussed.

About this research paper

What this paper is about

To investigate the flow characteristics including meter coefficient,linearity,uncertainty and lower flow limit of the vortex flowmeter under different medium densities,tremendous experiments are performed on the gas flow calibration facility based on barotropic venturi nozzles.The flowmeter with a diameter of 50 mm was calibrated at the air density of 2.774 kg/m~3,3.619 kg/m~3,4.782 kg/m~3 and 5.987 kg/m~3 respectively by adjusting the pressure in conduits from 0.23 MPa to 0.5 MPa.The results demonstrate that the maximum relative error of meter coefficient under different densities is 0.405%,which verifies that the medium density has little influence on the meter coefficient of vortex flowmeter.It is also found that the lower flow limit extends downward with the increase of medium density.And the reason for this phenomenon is discussed.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To investigate the flow characteristics including meter coefficient,linearity,uncertainty and lower flow limit of the vortex flowmeter under different medium densities,tremendous experiments are performed on the gas flow calibration facility based on barotropic venturi nozzles.The flowmeter with a diameter of 50 mm was calibrated at the air density of 2.774 kg/m~3,3.619 kg/m~3,4.782 kg/m~3 and 5.987 kg/m~3 respectively by adjusting the pressure in conduits from 0.23 MPa to 0.5 MPa.The results demonstrate that the maximum relative error of meter coefficient under different densities is 0.405%,which verifies that the medium density has little influence on the meter coefficient of vortex flowmeter.It is also found that the lower flow limit extends downward with the increase of medium density.And the reason for this phenomenon is discussed.

Key concepts: Flow measurement, Venturi effect, Ultrasonic flow meter, Thermal mass flow meter, Mechanics, Flow (mathematics), Positive displacement meter, Discharge coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Experiments on the Flow Characteristics of Gas Vortex Flowmeter under Different Medium Densities — Research Paper | ScholarLens