2013Building Energy & EnvironmentRequires access

Numerical Simulation and Experimental Study on Airflow Distribution and Thermal Comfort in Air-conditioning Room

Xie Don

Open publisher page 0 citations

Abstract

Based on the thermal comfort PMV index and PPD index proposed by Fanger,numerical modeling was used to research indoor thermal comfort environment on three different air distributions in summer and winter.Experimental investigation on indoor thermal comfort was carried out on the typical conditions in the standard airflow room,then numerical simulation results were compared with experimental results.We find the form of low air inlet-up air outlet is the best one of three air distributions.Research results provide reference to optimization design in airflow distribution and improvement in indoor thermal comfort environment of air-conditioning room.

About this research paper

What this paper is about

Based on the thermal comfort PMV index and PPD index proposed by Fanger,numerical modeling was used to research indoor thermal comfort environment on three different air distributions in summer and winter.Experimental investigation on indoor thermal comfort was carried out on the typical conditions in the standard airflow room,then numerical simulation results were compared with experimental results.We find the form of low air inlet-up air outlet is the best one of three air distributions.Research results provide reference to optimization design in airflow distribution and improvement in indoor thermal comfort environment of air-conditioning room.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Based on the thermal comfort PMV index and PPD index proposed by Fanger,numerical modeling was used to research indoor thermal comfort environment on three different air distributions in summer and winter.Experimental investigation on indoor thermal comfort was carried out on the typical conditions in the standard airflow room,then numerical simulation results were compared with experimental results.We find the form of low air inlet-up air outlet is the best one of three air distributions.Research results provide reference to optimization design in airflow distribution and improvement in indoor thermal comfort environment of air-conditioning room.

Key concepts: Thermal comfort, Airflow, Air conditioning, Environmental science, Room air distribution, Inlet, Thermal, Indoor air

Related papers

Back to paper searchBrowse research topicsOriginal source
Numerical Simulation and Experimental Study on Airflow Distribution and Thermal Comfort in Air-conditioning Room — Research Paper | ScholarLens