2002Industrial Water TreatmentRequires access

Determination of cadmium in wastewater by the high sensitive system of dye ion-pair of bromophenol blue-Butylrhodamine B

Liang Shu

Open publisher page 0 citations

Abstract

Cadmium is one of the heavy metals which have high toxicity and can be accumulated in bodies. Its content in environment is very low. In the determination of Cd, high sensitivity is required. A new detection method formed by two kinds of dye has been studied. Three components system of Cd-Phen-Bromophenol Blue(BPB) is first extracted by CHCl 3. Then the solution of Na 2CO 3 is added to destroy the three components system. Then Butylrhodamine B (BRB) is added to form dye ion pair with BPB. BPB-BRB ion pair is extracted by toluene. The absorbance is measured at 589 nm.The apparent molar absorptivity is 4.08×10 5 L/(mol·cm). Beers law is obeyed over the concentration range of 6.0×10 -8 ~3.1×10 -5 mol/L. The recovery rate is in the range of 98.0%~101.8%. RSD is 3.2%. The proposed method is applied to the determination of trace Cd in wastewater samples, and satisfactory results have been obtained.

About this research paper

What this paper is about

Cadmium is one of the heavy metals which have high toxicity and can be accumulated in bodies. Its content in environment is very low. In the determination of Cd, high sensitivity is required. A new detection method formed by two kinds of dye has been studied. Three components system of Cd-Phen-Bromophenol Blue(BPB) is first extracted by CHCl 3. Then the solution of Na 2CO 3 is added to destroy the three components system. Then Butylrhodamine B (BRB) is added to form dye ion pair with BPB. BPB-BRB ion pair is extracted by toluene. The absorbance is measured at 589 nm.The apparent molar absorptivity is 4.08×10 5 L/(mol·cm). Beers law is obeyed over the concentration range of 6.0×10 -8 ~3.1×10 -5 mol/L. The recovery rate is in the range of 98.0%~101.8%. RSD is 3.2%. The proposed method is applied to the determination of trace Cd in wastewater samples, and satisfactory results have been obtained.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cadmium is one of the heavy metals which have high toxicity and can be accumulated in bodies. Its content in environment is very low. In the determination of Cd, high sensitivity is required. A new detection method formed by two kinds of dye has been studied. Three components system of Cd-Phen-Bromophenol Blue(BPB) is first extracted by CHCl 3. Then the solution of Na 2CO 3 is added to destroy the three components system. Then Butylrhodamine B (BRB) is added to form dye ion pair with BPB. BPB-BRB ion pair is extracted by toluene. The absorbance is measured at 589 nm.The apparent molar absorptivity is 4.08×10 5 L/(mol·cm). Beers law is obeyed over the concentration range of 6.0×10 -8 ~3.1×10 -5 mol/L. The recovery rate is in the range of 98.0%~101.8%. RSD is 3.2%. The proposed method is applied to the determination of trace Cd in wastewater samples, and satisfactory results have been obtained.

Key concepts: Bromophenol blue, Absorbance, Chemistry, Molar absorptivity, Cadmium, Wastewater, Toluene, Nuclear chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of cadmium in wastewater by the high sensitive system of dye ion-pair of bromophenol blue-Butylrhodamine B — Research Paper | ScholarLens