2011•Electric Power ConstructionRequires access

Research on Maximum Allowable Operating Temperature of Aluminum Clad Steel Stranded Conductor

Wu Xin

Open publisher page 0 citations

Abstract

Aluminum clad steel stranded conductor has a bright application prospect in long span transmission line project because of its large tensional force and small sag.However,its application is limited due to its low ampacity.Based on the testing verification,the paper illustrates that the maximum allowable operating temperature of aluminum clad steel stranded conductor,can be increased up to 130 ℃ and its ampacity can be greatly increased as a result.This testing result gives us a new idea on designing long span transmission line projects.

About this research paper

What this paper is about

Aluminum clad steel stranded conductor has a bright application prospect in long span transmission line project because of its large tensional force and small sag.However,its application is limited due to its low ampacity.Based on the testing verification,the paper illustrates that the maximum allowable operating temperature of aluminum clad steel stranded conductor,can be increased up to 130 ℃ and its ampacity can be greatly increased as a result.This testing result gives us a new idea on designing long span transmission line projects.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aluminum clad steel stranded conductor has a bright application prospect in long span transmission line project because of its large tensional force and small sag.However,its application is limited due to its low ampacity.Based on the testing verification,the paper illustrates that the maximum allowable operating temperature of aluminum clad steel stranded conductor,can be increased up to 130 ℃ and its ampacity can be greatly increased as a result.This testing result gives us a new idea on designing long span transmission line projects.

Key concepts: Ampacity, Conductor, Span (engineering), Transmission line, Engineering, Aluminium, Structural engineering, Electric power transmission

Related papers

Back to paper searchBrowse research topicsOriginal source
Research on Maximum Allowable Operating Temperature of Aluminum Clad Steel Stranded Conductor — Research Paper | ScholarLens