Exergy Analysis of Low-temperature Water Heat Pump Operation

Xiaolin Zhu

Open publisher page 0 citations

Abstract

In this paper,we introduced the method of exergy analysis and evaluated the course of low-temperature water heat pump operation.Under the water temperature specified as 10℃ and 15℃,the exergy deduction of heat pump unit was obtained to 1.22kw and 1.04kw,respectively,the exergy efficiency of heat pump was obtained to 21% and 33%,respectively.The influence extent to system efficiency of facilities was specified by the method of exergy deduction and exergy efficiency calculation to each equipment in the system.After calculation,the compressor was considered the biggest influence factor.Also,changing the reference state,comparing the system exergy deduction and exergy efficiency in the different environment temperature,we could depict graph to analyze the system exergy deduction and exergy efficiency when altering the environment temperature.

About this research paper

What this paper is about

In this paper,we introduced the method of exergy analysis and evaluated the course of low-temperature water heat pump operation.Under the water temperature specified as 10℃ and 15℃,the exergy deduction of heat pump unit was obtained to 1.22kw and 1.04kw,respectively,the exergy efficiency of heat pump was obtained to 21% and 33%,respectively.The influence extent to system efficiency of facilities was specified by the method of exergy deduction and exergy efficiency calculation to each equipment in the system.After calculation,the compressor was considered the biggest influence factor.Also,changing the reference state,comparing the system exergy deduction and exergy efficiency in the different environment temperature,we could depict graph to analyze the system exergy deduction and exergy efficiency when altering the environment temperature.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In this paper,we introduced the method of exergy analysis and evaluated the course of low-temperature water heat pump operation.Under the water temperature specified as 10℃ and 15℃,the exergy deduction of heat pump unit was obtained to 1.22kw and 1.04kw,respectively,the exergy efficiency of heat pump was obtained to 21% and 33%,respectively.The influence extent to system efficiency of facilities was specified by the method of exergy deduction and exergy efficiency calculation to each equipment in the system.After calculation,the compressor was considered the biggest influence factor.Also,changing the reference state,comparing the system exergy deduction and exergy efficiency in the different environment temperature,we could depict graph to analyze the system exergy deduction and exergy efficiency when altering the environment temperature.

Key concepts: Exergy, Exergy efficiency, Gas compressor, Heat pump, Process engineering, Environmental science, Thermodynamics, Engineering