2007Electrical EquipmentRequires access

Case Study and Judgment on Breakdown Fault of Vacuum Vessel for High Voltage Circuit Breaker

Faxian Yu

Open publisher page 0 citations

Abstract

The technology of cubicle type circuit breaker has become more and more application. The circuit breaker of generator outlet in Anhui Xianggongmiao hydropower station is this kind of circuit breaker. The paper introduced the course of case study, handling and the judgment after breakdown fault of the vacuum vessel for high voltage circuit breaker of No. 2 generator in the hydropower station. It is pointed out that because of concealing characteristics of cubicle type high voltage circuit breaker, it is difficult to analyze and check after occurring breakdown fault of vacuum vessel, thus at present technical level, this kind of circuit breaker is unfit for to be used in outlet of generator.

About this research paper

What this paper is about

The technology of cubicle type circuit breaker has become more and more application. The circuit breaker of generator outlet in Anhui Xianggongmiao hydropower station is this kind of circuit breaker. The paper introduced the course of case study, handling and the judgment after breakdown fault of the vacuum vessel for high voltage circuit breaker of No. 2 generator in the hydropower station. It is pointed out that because of concealing characteristics of cubicle type high voltage circuit breaker, it is difficult to analyze and check after occurring breakdown fault of vacuum vessel, thus at present technical level, this kind of circuit breaker is unfit for to be used in outlet of generator.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The technology of cubicle type circuit breaker has become more and more application. The circuit breaker of generator outlet in Anhui Xianggongmiao hydropower station is this kind of circuit breaker. The paper introduced the course of case study, handling and the judgment after breakdown fault of the vacuum vessel for high voltage circuit breaker of No. 2 generator in the hydropower station. It is pointed out that because of concealing characteristics of cubicle type high voltage circuit breaker, it is difficult to analyze and check after occurring breakdown fault of vacuum vessel, thus at present technical level, this kind of circuit breaker is unfit for to be used in outlet of generator.

Key concepts: Circuit breaker, Arc-fault circuit interrupter, Engineering, Sulfur hexafluoride circuit breaker, Residual-current device, Electrical engineering, Transient recovery voltage, Fault (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Case Study and Judgment on Breakdown Fault of Vacuum Vessel for High Voltage Circuit Breaker — Research Paper | ScholarLens