Simultaneous determination of F~-、Cl~-、NO_3~-、PO_4~(3-)、SO_4~(2-)、BrO_3~-、Br~-、NO_2~- in tea by IC with hydrophobic column AS-15
Fuyuan Tan
Abstract
Fuyuan Tan
Abstract
Based on gradient elution method,ion chromatography(IC) with the hydrophobic column AS-15 was developed to simultaneously determine the content of inorganic anions(i.e.,F-,Cl-,NO3-,PO43-,SO42-,BrO3-,Br-and NO2-) in tea.Firstly,the tea powders were soaking in boiling water for 5 min at the ratio of tea to water as 1:50.Then,the powders were filtered out,and the filtrate was stabilized for 30 min.The prepared solution was treated by activated carbon cartridge,and the collected solution was filtered through a 0.20 μm filter membrane before injection.The results showed that the 8 inorganic anions were thoroughly separated,the contents of anions and peak areas gave a good linear relationship,the detection limit was less than 0.056 mg/L,and their recoveries in the range from 96.5% to 105.1%.The established method is robust,and it can be used for the routine determination of inorganic anions with sound repeatability.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Based on gradient elution method,ion chromatography(IC) with the hydrophobic column AS-15 was developed to simultaneously determine the content of inorganic anions(i.e.,F-,Cl-,NO3-,PO43-,SO42-,BrO3-,Br-and NO2-) in tea.Firstly,the tea powders were soaking in boiling water for 5 min at the ratio of tea to water as 1:50.Then,the powders were filtered out,and the filtrate was stabilized for 30 min.The prepared solution was treated by activated carbon cartridge,and the collected solution was filtered through a 0.20 μm filter membrane before injection.The results showed that the 8 inorganic anions were thoroughly separated,the contents of anions and peak areas gave a good linear relationship,the detection limit was less than 0.056 mg/L,and their recoveries in the range from 96.5% to 105.1%.The established method is robust,and it can be used for the routine determination of inorganic anions with sound repeatability.
Key concepts: Chemistry, Detection limit, Repeatability, Cartridge, Chromatography, Elution, Boiling, Ion chromatography