1999PubMedRequires access

[Experimental study and clinical application on osteogenesis of percutaneous autogenous bone marrow grafting in bone defects].

Liang Yt, Zhang Bx, Lu Sb

Open publisher page 2 citations

Abstract

OBJECTIVE: To observe the osteogenesis of percutaneous autogenous bone marrow grafting in cicatricial bone defect, to seek a good method for treating fracture nonunion. METHODS: Eighteen rabbits were adopted in this study. 1 cm bone defect model was made in each side of radius, 6 weeks later, 2 ml autogenous bone marrow was injected in the right radial bone defect as experimental group, 2 ml autogenous peripheral blood in the left side as control group. X-ray features, histologic changes, Ca and P content in the site of bone defect were studied in various times. Also 15 patients were treated clinically for the nonunion fracture, the average time from nonunion to bone marrow grafting was 13 months. RESULTS: In experimental group, the increasing new bone tissue were observed in X-ray and histologic examination. While in control group, no osteogenesis was observed. Ca and P content of experimental group was higher than that of control group. For the 15 patients, 13 cases healed in 5-9 months, 2 cases failed. CONCLUSION: Percutaneous autogenous bone marrow grafting is capable of osteogenesis in the cicatricial bone defects. It can be used in nonunion cases which are not fit for operation of bone grafting because of poor condition of the skin.

About this research paper

What this paper is about

OBJECTIVE: To observe the osteogenesis of percutaneous autogenous bone marrow grafting in cicatricial bone defect, to seek a good method for treating fracture nonunion. METHODS: Eighteen rabbits were adopted in this study. 1 cm bone defect model was made in each side of radius, 6 weeks later, 2 ml autogenous bone marrow was injected in the right radial bone defect as experimental group, 2 ml autogenous peripheral blood in the left side as control group. X-ray features, histologic changes, Ca and P content in the site of bone defect were studied in various times. Also 15 patients were treated clinically for the nonunion fracture, the average time from nonunion to bone marrow grafting was 13 months. RESULTS: In experimental group, the increasing new bone tissue were observed in X-ray and histologic examination. While in control group, no osteogenesis was observed. Ca and P content of experimental group was higher than that of control group. For the 15 patients, 13 cases healed in 5-9 months, 2 cases failed. CONCLUSION: Percutaneous autogenous bone marrow grafting is capable of osteogenesis in the cicatricial bone defects. It can be used in nonunion cases which are not fit for operation of bone grafting because of poor condition of the skin.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To observe the osteogenesis of percutaneous autogenous bone marrow grafting in cicatricial bone defect, to seek a good method for treating fracture nonunion. METHODS: Eighteen rabbits were adopted in this study. 1 cm bone defect model was made in each side of radius, 6 weeks later, 2 ml autogenous bone marrow was injected in the right radial bone defect as experimental group, 2 ml autogenous peripheral blood in the left side as control group. X-ray features, histologic changes, Ca and P content in the site of bone defect were studied in various times. Also 15 patients were treated clinically for the nonunion fracture, the average time from nonunion to bone marrow grafting was 13 months. RESULTS: In experimental group, the increasing new bone tissue were observed in X-ray and histologic examination. While in control group, no osteogenesis was observed. Ca and P content of experimental group was higher than that of control group. For the 15 patients, 13 cases healed in 5-9 months, 2 cases failed. CONCLUSION: Percutaneous autogenous bone marrow grafting is capable of osteogenesis in the cicatricial bone defects. It can be used in nonunion cases which are not fit for operation of bone grafting because of poor condition of the skin.

Key concepts: Nonunion, Medicine, Bone healing, Bone grafting, Bone marrow, Percutaneous, Surgery, Grafting

Related papers

Back to paper searchBrowse research topicsOriginal source
[Experimental study and clinical application on osteogenesis of percutaneous autogenous bone marrow grafting in bone defects]. — Research Paper | ScholarLens