EC_(50) of continuous epidural sufentanil infusion analgesia after gynecological surgery
Quancheng Kan
Abstract
Quancheng Kan
Abstract
OBJECTIVE To determine the median effective concentration(EC50) of continuous epidural sufentainil infusion analgesia after gynecological surgery.METHODS Forty ASA Ⅰ or Ⅱ patients aged 20-50 yr with body weight index30 kg·m-2 undergoing elective lower abdominal gynecological operation under epidural anesthesia received continuous epidural sufentanil infusion(CEI) for 48h.epidural catheter was placed at L1-2.CEI device was set up to deliver sufentanil solution at 2 mL·h-1 after a loading dose of 5 mL.The EC50 of sufentanil was determined by up and down sequential test.The concentration of sufentanil was increased or decreased with ratio of 1.2.If effective,the next patient received sufentanil at a lower concentration,if ineffective a higher concentration.VAS(0-10,0=no pain,10=worst pain)was used to assess the analgesia.If the VAS score was ≦3 within 8h after sufentanil administration,analgesia was defined as effective.The up and down sequences were analyzed by using Dixon method to determine the EC50 and 95% confidence interval(CI).The side effects were also recorded.RESULTS The EC50 of sufentanil CEI was 0.87 mg L-1.95% confidence interval was between 0.79 mg·L-1 and 0.96 mg·L-1.The incidence of pruritus was 3.8%.There were 3 patients who had nausea and vomiting.No patients had respiratory depression.CONCLUSION The EC50 of continuous epidural sufentanil infusion analgesia after gynecological surgery was 0.87 mg·L-1.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE To determine the median effective concentration(EC50) of continuous epidural sufentainil infusion analgesia after gynecological surgery.METHODS Forty ASA Ⅰ or Ⅱ patients aged 20-50 yr with body weight index30 kg·m-2 undergoing elective lower abdominal gynecological operation under epidural anesthesia received continuous epidural sufentanil infusion(CEI) for 48h.epidural catheter was placed at L1-2.CEI device was set up to deliver sufentanil solution at 2 mL·h-1 after a loading dose of 5 mL.The EC50 of sufentanil was determined by up and down sequential test.The concentration of sufentanil was increased or decreased with ratio of 1.2.If effective,the next patient received sufentanil at a lower concentration,if ineffective a higher concentration.VAS(0-10,0=no pain,10=worst pain)was used to assess the analgesia.If the VAS score was ≦3 within 8h after sufentanil administration,analgesia was defined as effective.The up and down sequences were analyzed by using Dixon method to determine the EC50 and 95% confidence interval(CI).The side effects were also recorded.RESULTS The EC50 of sufentanil CEI was 0.87 mg L-1.95% confidence interval was between 0.79 mg·L-1 and 0.96 mg·L-1.The incidence of pruritus was 3.8%.There were 3 patients who had nausea and vomiting.No patients had respiratory depression.CONCLUSION The EC50 of continuous epidural sufentanil infusion analgesia after gynecological surgery was 0.87 mg·L-1.
Key concepts: Sufentanil, Medicine, Anesthesia, Nausea, Vomiting, Confidence interval, Gynecological surgery, Abdominal surgery