2007Journal of Instrumental AnalysisRequires access

Spectrophotometric Determination of Cationic Surfactants with Congo Red

Rong Tan

Open publisher page 0 citations

Abstract

A spectrophotometric method was developed for the determination of cationic surfactant.It is based on the discoloration of Congo red(CR)while forming the ion-association complex between the cationic surfactant(CS) and CR in weak acidic HCl-NaAc buffer medium.Spectrophotometric data showed that the maximum discoloration wavelength for CR-cetyl pyridinium bromide(CPB) system was 510 nm and that for CR-Cetyl trimethyl ammonium bromide(CTAB) system was 514 nm.The linear range of the calibration curve,the apparent molar absorptivity and the detection limit for CR-CPB system at 510 nm were 0-4.16×10-5 mol·L-1,1.62×104 L/(mol·cm),and 9.78×10-7 mol·L-1 respectively;and those for CR-CTAB system at 514 nm were 0-3.18×10-5 mol·L1,1.72×104 L/(mol·cm) and 1.04×10-6 mol·L-1, respectively.The method has been applied to the determination of CS in water samples with satisfactory results.

About this research paper

What this paper is about

A spectrophotometric method was developed for the determination of cationic surfactant.It is based on the discoloration of Congo red(CR)while forming the ion-association complex between the cationic surfactant(CS) and CR in weak acidic HCl-NaAc buffer medium.Spectrophotometric data showed that the maximum discoloration wavelength for CR-cetyl pyridinium bromide(CPB) system was 510 nm and that for CR-Cetyl trimethyl ammonium bromide(CTAB) system was 514 nm.The linear range of the calibration curve,the apparent molar absorptivity and the detection limit for CR-CPB system at 510 nm were 0-4.16×10-5 mol·L-1,1.62×104 L/(mol·cm),and 9.78×10-7 mol·L-1 respectively;and those for CR-CTAB system at 514 nm were 0-3.18×10-5 mol·L1,1.72×104 L/(mol·cm) and 1.04×10-6 mol·L-1, respectively.The method has been applied to the determination of CS in water samples with satisfactory results.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A spectrophotometric method was developed for the determination of cationic surfactant.It is based on the discoloration of Congo red(CR)while forming the ion-association complex between the cationic surfactant(CS) and CR in weak acidic HCl-NaAc buffer medium.Spectrophotometric data showed that the maximum discoloration wavelength for CR-cetyl pyridinium bromide(CPB) system was 510 nm and that for CR-Cetyl trimethyl ammonium bromide(CTAB) system was 514 nm.The linear range of the calibration curve,the apparent molar absorptivity and the detection limit for CR-CPB system at 510 nm were 0-4.16×10-5 mol·L-1,1.62×104 L/(mol·cm),and 9.78×10-7 mol·L-1 respectively;and those for CR-CTAB system at 514 nm were 0-3.18×10-5 mol·L1,1.72×104 L/(mol·cm) and 1.04×10-6 mol·L-1, respectively.The method has been applied to the determination of CS in water samples with satisfactory results.

Key concepts: Chemistry, Molar absorptivity, Cationic polymerization, Pulmonary surfactant, Ammonium bromide, Congo red, Bromide, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
Spectrophotometric Determination of Cationic Surfactants with Congo Red — Research Paper | ScholarLens