2010•Industrial Safety and Environmental ProtectionRequires access

Numerical Simulation on Smoke Exhaust Effect by Different Smoke Exhaust Rates in High-rise Building Fires

Jingxian Li

Open publisher page 0 citations

Abstract

Comparative analysis are made on smoke diffusion,temperature variation and the changing of smoke layer depth under smoke vent,when smoke exhaust rates are different.The results show that different smoke exhaust rates have great influence on smoke exhaust effect.In Code for Fire Protection Design of Tall Buildings,the criterion 'the air speed at smoke vent shouldn't be more than 10m/s'isn't reasonable.When making smoke exhaust design for high-rise building corridor,a reasonable smoke exhaust rate should be taken,to ensure that the controlling distance of smoke vent is less than the smoke layer depth,by concept of performance-based fire protection design.

About this research paper

What this paper is about

Comparative analysis are made on smoke diffusion,temperature variation and the changing of smoke layer depth under smoke vent,when smoke exhaust rates are different.The results show that different smoke exhaust rates have great influence on smoke exhaust effect.In Code for Fire Protection Design of Tall Buildings,the criterion 'the air speed at smoke vent shouldn't be more than 10m/s'isn't reasonable.When making smoke exhaust design for high-rise building corridor,a reasonable smoke exhaust rate should be taken,to ensure that the controlling distance of smoke vent is less than the smoke layer depth,by concept of performance-based fire protection design.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Comparative analysis are made on smoke diffusion,temperature variation and the changing of smoke layer depth under smoke vent,when smoke exhaust rates are different.The results show that different smoke exhaust rates have great influence on smoke exhaust effect.In Code for Fire Protection Design of Tall Buildings,the criterion 'the air speed at smoke vent shouldn't be more than 10m/s'isn't reasonable.When making smoke exhaust design for high-rise building corridor,a reasonable smoke exhaust rate should be taken,to ensure that the controlling distance of smoke vent is less than the smoke layer depth,by concept of performance-based fire protection design.

Key concepts: Smoke, Environmental science, Exhaust gas, Waste management, High rise, Environmental engineering, Meteorology, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Numerical Simulation on Smoke Exhaust Effect by Different Smoke Exhaust Rates in High-rise Building Fires — Research Paper | ScholarLens