[Analysis of therapeutic effects of external fixator for the treatment of comminuted fracture of distal radius].
Huajun Zhang, Shu-jin Wang, Zhou Li-jian, Wang Yao-wei
Abstract
Huajun Zhang, Shu-jin Wang, Zhou Li-jian, Wang Yao-wei
Abstract
OBJECTIVE: To evaluate the clinical effects of external fixator in treating comminuted fracture of distal radius. METHODS: From Mar.2008 to Dec.2009, 37 patients with comminuted fracture of distal radius were treated with external fixator or assisted with Kirschner wire and T-shape locking compression plate (T-LCP) fixation. There were 14 males and 23 females, ranging in age from 30 to 79 years, with an average of 59.1 years. According to AO typing, type C1 was in 3 cases, type C2 was in 11 cases and type C3 was in 23 cases. Function of wrist joint and X-ray films were observed according to Gratland-Werley system at different months. RESULTS: All patients were followed up from 8 to 24 months with an average of 12 months. All fractures had healing with an average time of 8 weeks. According to Gratland-Werley system, 16 cases obtained excellent result, 17 good, 4 fair, the rate of excellent and good was 89.0%. CONCLUSION: External fixator can obtained satisfactory clinical effect in treating comminuted fracture of distal radius.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
OBJECTIVE: To evaluate the clinical effects of external fixator in treating comminuted fracture of distal radius. METHODS: From Mar.2008 to Dec.2009, 37 patients with comminuted fracture of distal radius were treated with external fixator or assisted with Kirschner wire and T-shape locking compression plate (T-LCP) fixation. There were 14 males and 23 females, ranging in age from 30 to 79 years, with an average of 59.1 years. According to AO typing, type C1 was in 3 cases, type C2 was in 11 cases and type C3 was in 23 cases. Function of wrist joint and X-ray films were observed according to Gratland-Werley system at different months. RESULTS: All patients were followed up from 8 to 24 months with an average of 12 months. All fractures had healing with an average time of 8 weeks. According to Gratland-Werley system, 16 cases obtained excellent result, 17 good, 4 fair, the rate of excellent and good was 89.0%. CONCLUSION: External fixator can obtained satisfactory clinical effect in treating comminuted fracture of distal radius.
Key concepts: Medicine, External fixator, Wrist, External fixation, Surgery, Distal radius fracture, Kirschner wire, Fixation (population genetics)