2003Journal of Tianjin University Science and TechnologyRequires access

Difference of Quantity Analysis with Quadrupole Mass Detector and Flame Ionization Detector in Gas Chromatography

Guoliang Fan

Open publisher page 1 citations

Abstract

The quantity analyses were compared wi th quadrupole mass detector and flame ionization detector in gas chromatography-m ass spectrometer and gas chromatography. The results were quite different when the calibration factor was not used in analysis under common condition. The reas on of causing these results was discussed. The condition of obtaining exact resu lt without using calibration factor was described in gas chromatography-mass sp ectrometer.

About this research paper

What this paper is about

The quantity analyses were compared wi th quadrupole mass detector and flame ionization detector in gas chromatography-m ass spectrometer and gas chromatography. The results were quite different when the calibration factor was not used in analysis under common condition. The reas on of causing these results was discussed. The condition of obtaining exact resu lt without using calibration factor was described in gas chromatography-mass sp ectrometer.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The quantity analyses were compared wi th quadrupole mass detector and flame ionization detector in gas chromatography-m ass spectrometer and gas chromatography. The results were quite different when the calibration factor was not used in analysis under common condition. The reas on of causing these results was discussed. The condition of obtaining exact resu lt without using calibration factor was described in gas chromatography-mass sp ectrometer.

Key concepts: Gas chromatography, Detector, Flame ionization detector, Helium ionization detector, Discharge ionization detector, Mass spectrometry, Calibration, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Difference of Quantity Analysis with Quadrupole Mass Detector and Flame Ionization Detector in Gas Chromatography — Research Paper | ScholarLens