Determination of the Migration of Non-phthalate Plasticizer DINCH in Plastic Food Packaging Materials by GC-MS
Xia Yang
Abstract
Xia Yang
Abstract
The migration of non-phthalate plasticizer, di(isononyl) cyclohexane-1,2-dicarboxylate(DINCH) in plastic food packaging materials was evaluated by GC-MS. Distilled water, 3%(V/V) acetic acid aqueous solution and 15%(V/V) ethanol a queous solution were used as aqueous food stimulants and isooctane as a fatty food stimulant. The aqueous food stimulants were extracted with n-hexane after food packaging materials were immersed in each of them. After being used to immerse samples, the fatty food stimulant was blown to dryness by nitrogen and then re-dissolved and diltetedin n-hexane direct injection. The results showed that the linear range was between 10 μg/mL and 400 μg/mL(r = 0.9999), and the recoveries of DINCH ranged from 95.2% to 103.4% with relative standard deviation(RSD) of less than 5% in four stimulants. The developed method is accurate and repeatable. It can be used for the evaluation of DINCH migration in p lastic food packaging materials.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The migration of non-phthalate plasticizer, di(isononyl) cyclohexane-1,2-dicarboxylate(DINCH) in plastic food packaging materials was evaluated by GC-MS. Distilled water, 3%(V/V) acetic acid aqueous solution and 15%(V/V) ethanol a queous solution were used as aqueous food stimulants and isooctane as a fatty food stimulant. The aqueous food stimulants were extracted with n-hexane after food packaging materials were immersed in each of them. After being used to immerse samples, the fatty food stimulant was blown to dryness by nitrogen and then re-dissolved and diltetedin n-hexane direct injection. The results showed that the linear range was between 10 μg/mL and 400 μg/mL(r = 0.9999), and the recoveries of DINCH ranged from 95.2% to 103.4% with relative standard deviation(RSD) of less than 5% in four stimulants. The developed method is accurate and repeatable. It can be used for the evaluation of DINCH migration in p lastic food packaging materials.
Key concepts: Plasticizer, Phthalate, Food packaging, Aqueous solution, Chemistry, Acetic acid, Chromatography, Food science