2007•Physical Testing and Chemical AnalysisRequires access

Determination of Oxytetracycline,Doxycycline,Tetracycline and Chlortetracycline in Tetracycline Antibiotics by HPLC

Feng Chen, Yue Jiang

Open publisher page 0 citations

Abstract

A rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of oxytetracycline,doxycycline,tetracycline and chlortetracycline was developed.The separation was performed on a reverse-phase C18 column with gradient elution using a mixed solution composed of methanol and sodium acetate buffer(containing disodium salt of EDTA and calcium chloride,pH 8.10).UV detection at 386 nm was used,linearity of the calibration curve was obtained in the range of 8-4 000 μg·L-1.The detection limits for oxytetracycline,doxycycline,tetracycline and chlortetracycline were 6,13,6 and 7 μg·L-1 respectively.The method has been applied to the analysis of commercial tetracycline antibiotics,giving RSD′s in the range from 1.2% to 3.6%,and recoveries from 95% to 102%.

About this research paper

What this paper is about

A rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of oxytetracycline,doxycycline,tetracycline and chlortetracycline was developed.The separation was performed on a reverse-phase C18 column with gradient elution using a mixed solution composed of methanol and sodium acetate buffer(containing disodium salt of EDTA and calcium chloride,pH 8.10).UV detection at 386 nm was used,linearity of the calibration curve was obtained in the range of 8-4 000 μg·L-1.The detection limits for oxytetracycline,doxycycline,tetracycline and chlortetracycline were 6,13,6 and 7 μg·L-1 respectively.The method has been applied to the analysis of commercial tetracycline antibiotics,giving RSD′s in the range from 1.2% to 3.6%,and recoveries from 95% to 102%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of oxytetracycline,doxycycline,tetracycline and chlortetracycline was developed.The separation was performed on a reverse-phase C18 column with gradient elution using a mixed solution composed of methanol and sodium acetate buffer(containing disodium salt of EDTA and calcium chloride,pH 8.10).UV detection at 386 nm was used,linearity of the calibration curve was obtained in the range of 8-4 000 μg·L-1.The detection limits for oxytetracycline,doxycycline,tetracycline and chlortetracycline were 6,13,6 and 7 μg·L-1 respectively.The method has been applied to the analysis of commercial tetracycline antibiotics,giving RSD′s in the range from 1.2% to 3.6%,and recoveries from 95% to 102%.

Key concepts: Oxytetracycline, Chlortetracycline, Tetracycline, Doxycycline, Chromatography, Chemistry, Tetracycline antibiotics, High-performance liquid chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Oxytetracycline,Doxycycline,Tetracycline and Chlortetracycline in Tetracycline Antibiotics by HPLC — Research Paper | ScholarLens