Shielding Calculation and Analysis of 10 MW High-Temperature Gas-Cooled Reactor
Yang Yong-wei
Abstract
Yang Yong-wei
Abstract
The high-temperature gas-cooled reactor is the important one in the generation Ⅳ nuclear system.Because of its large volume and complex structure,its shielding calculation is difficult.In this paper,shielding calculation of 10 MW High-Temperature Gas-Cooled Reactor was carried out by using TORT code,and the result was compared with those from ANISN and MCNP code.The comparison results show that they meet well.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The high-temperature gas-cooled reactor is the important one in the generation Ⅳ nuclear system.Because of its large volume and complex structure,its shielding calculation is difficult.In this paper,shielding calculation of 10 MW High-Temperature Gas-Cooled Reactor was carried out by using TORT code,and the result was compared with those from ANISN and MCNP code.The comparison results show that they meet well.
Key concepts: Electromagnetic shielding, Nuclear engineering, Materials science, Radiation shielding, Volume (thermodynamics), Physics, Engineering, Thermodynamics