2008Jiangsu Electrical ApparatusRequires access

Condition Based Maintenance Technology of High-Voltage Switchgears

Chen Zhen-sheng

Open publisher page 0 citations

Abstract

Metal switchgear cabinet inside and circuit breaker contacts temperature rise,circuit breaker mechanical characteristics and circuit breaker contacts arc burning wearing are main causes to cause switchgear equipment faulting,to carry out effective real-time monitor-ing is the key to achieve switchgear maintenance transfer.Introduction was made to CG2061 type high-voltage circuit breaker contacts tem-perature rise on-line measurement principle and application and permanent magnetic operating mechanism circuit breaker remote monitoring technology and circuit breaker contacts arc burning wearing monitoring technology.Analysis was made to circuit breaker breaking action coil current wave form and dynamic iron core displacement relationship.Example were made to calculation method of circuit breaker short circuit breaking off current and breaking off times,pointed out that to take operation matured on-line monitoring technology into design and manufacture can reduce the installation cost of electrical appliance prduct in on-line monitoring system unit reducing unnecessary work.

About this research paper

What this paper is about

Metal switchgear cabinet inside and circuit breaker contacts temperature rise,circuit breaker mechanical characteristics and circuit breaker contacts arc burning wearing are main causes to cause switchgear equipment faulting,to carry out effective real-time monitor-ing is the key to achieve switchgear maintenance transfer.Introduction was made to CG2061 type high-voltage circuit breaker contacts tem-perature rise on-line measurement principle and application and permanent magnetic operating mechanism circuit breaker remote monitoring technology and circuit breaker contacts arc burning wearing monitoring technology.Analysis was made to circuit breaker breaking action coil current wave form and dynamic iron core displacement relationship.Example were made to calculation method of circuit breaker short circuit breaking off current and breaking off times,pointed out that to take operation matured on-line monitoring technology into design and manufacture can reduce the installation cost of electrical appliance prduct in on-line monitoring system unit reducing unnecessary work.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Metal switchgear cabinet inside and circuit breaker contacts temperature rise,circuit breaker mechanical characteristics and circuit breaker contacts arc burning wearing are main causes to cause switchgear equipment faulting,to carry out effective real-time monitor-ing is the key to achieve switchgear maintenance transfer.Introduction was made to CG2061 type high-voltage circuit breaker contacts tem-perature rise on-line measurement principle and application and permanent magnetic operating mechanism circuit breaker remote monitoring technology and circuit breaker contacts arc burning wearing monitoring technology.Analysis was made to circuit breaker breaking action coil current wave form and dynamic iron core displacement relationship.Example were made to calculation method of circuit breaker short circuit breaking off current and breaking off times,pointed out that to take operation matured on-line monitoring technology into design and manufacture can reduce the installation cost of electrical appliance prduct in on-line monitoring system unit reducing unnecessary work.