2011•Shipin yanjiu yu kaifaRequires access

Determine Proanthocyanidins in Grape Seed Extract with Proanthocyanidin B2 Standard

Yingying Fu

Open publisher page 0 citations

Abstract

To establish a method for detecting proanthocyanidins in grape seed extract with proanthocyanidin B2 standard.Refer to the Bate-Smith method,using proanthocyanidin B2(≥99;HPLC) to calibrate proanthocyanidins in grape seed extract at 546 nm.Linear range of proanthocyanidins is 22.89 μg/mL-114.5 μg/mL(r=0.999 02,n=5),Recovery∶97.99 %,RSD∶1.02 %(n=6).Using single ingredient proanthocyanidin B2 standard calibrated by HPLC to calibrate proanthocyanidins,resolving the problem that the standard content is not identical and can not convince when using proanthocyanidin compound standard.The method have better linearity and repeatability,can detect grape seed extract's proanthocyanidins exactly.

About this research paper

What this paper is about

To establish a method for detecting proanthocyanidins in grape seed extract with proanthocyanidin B2 standard.Refer to the Bate-Smith method,using proanthocyanidin B2(≥99;HPLC) to calibrate proanthocyanidins in grape seed extract at 546 nm.Linear range of proanthocyanidins is 22.89 μg/mL-114.5 μg/mL(r=0.999 02,n=5),Recovery∶97.99 %,RSD∶1.02 %(n=6).Using single ingredient proanthocyanidin B2 standard calibrated by HPLC to calibrate proanthocyanidins,resolving the problem that the standard content is not identical and can not convince when using proanthocyanidin compound standard.The method have better linearity and repeatability,can detect grape seed extract's proanthocyanidins exactly.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish a method for detecting proanthocyanidins in grape seed extract with proanthocyanidin B2 standard.Refer to the Bate-Smith method,using proanthocyanidin B2(≥99;HPLC) to calibrate proanthocyanidins in grape seed extract at 546 nm.Linear range of proanthocyanidins is 22.89 μg/mL-114.5 μg/mL(r=0.999 02,n=5),Recovery∶97.99 %,RSD∶1.02 %(n=6).Using single ingredient proanthocyanidin B2 standard calibrated by HPLC to calibrate proanthocyanidins,resolving the problem that the standard content is not identical and can not convince when using proanthocyanidin compound standard.The method have better linearity and repeatability,can detect grape seed extract's proanthocyanidins exactly.

Key concepts: Proanthocyanidin, Grape seed, Chemistry, Repeatability, Ingredient, Grape seed extract, Food science, Chromatography

Related papers

Back to paper searchBrowse research topicsOriginal source
Determine Proanthocyanidins in Grape Seed Extract with Proanthocyanidin B2 Standard — Research Paper | ScholarLens