Research and Development of 800kV High-voltage AC Disconnector
Peng Kang
Abstract
Peng Kang
Abstract
The disconnector is a circuit switching equipment used in no load condition.In 2005,China took the lead in the Northwest power grid construction,the first 750 kV line and substation installation height of about 2 000 m above sea level.Therefore,the development for high altitude areas of the 800 kV high-voltage AC disconnector is an important topic in high-voltage power field,have a significant role in engineering applications.This article based on reviews of the foreign 800 kV UHV disconnector development,and through the discussion and research of 800 kV high-voltage disconnector insulation distance calculation,grading ring design and some technical parameters,some preliminary conclusion are drawn.According to the environmental characteristics of the northwest area in China,study line statistical withstand voltage calculations to determine the high altitude of 800 kV high-voltage AC disconnector insulation parameters and to develop 800 kV high-voltage AC disconnector of structural parameters for the development of 800 kV high-voltage AC disconnect switch provides the technical support.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
The disconnector is a circuit switching equipment used in no load condition.In 2005,China took the lead in the Northwest power grid construction,the first 750 kV line and substation installation height of about 2 000 m above sea level.Therefore,the development for high altitude areas of the 800 kV high-voltage AC disconnector is an important topic in high-voltage power field,have a significant role in engineering applications.This article based on reviews of the foreign 800 kV UHV disconnector development,and through the discussion and research of 800 kV high-voltage disconnector insulation distance calculation,grading ring design and some technical parameters,some preliminary conclusion are drawn.According to the environmental characteristics of the northwest area in China,study line statistical withstand voltage calculations to determine the high altitude of 800 kV high-voltage AC disconnector insulation parameters and to develop 800 kV high-voltage AC disconnector of structural parameters for the development of 800 kV high-voltage AC disconnect switch provides the technical support.
Key concepts: Disconnector, Electrical engineering, High voltage, Voltage, Engineering, Ground, Effects of high altitude on humans, Line (geometry)